Operating Manual CMGZ434
32
Limit 2 min / max
Use:
The digital output „Limit value 2“ can be set as a min- or a max limit
switch. That means, that the digital output will be activated when passing
over resp. passing under the value set under parameter
Limit value 2
.
Range:
Min,
Max
Default:
Min
Limit value 2
Use:
The digital output „Limit value 2“ will be activated if the threshold
value stored in this parameter is passed over resp. under (according to
setting in parameter
Limit 2 min / max
).
Range:
-9999
to
9999
Default:
0
Increment:
1
Unit:
[N,kN]
Language
Use:
With this parameter, the language in the display can be chosen.
Range:
English, German, French, Italian
Line speed overlay
Use:
If this parameter is set to
Yes
, the actual line speed signal is overlayed
to the PID controller output. This will increase controller dynamics
significantly. Refer to „9.9 Setup of line speed overlay“
Range:
No,
Yes
Default:
No
Influence of PI
Use:
If pilot control is activated, this parameter defines the percentage
participation of the PI resp. PID controller which will be added to the
pilot control signal.
„10%“ means 10% of the maximum output signal.
If parameter
Output limit
is set to less than 100% the influence value
stored here should be adjusted accordingly.
If pilot control is not activated, the effective influence of PI resp. PID
is 100%, independent of this parameter.
Range:
0.1
to
100
Default:
100.0
Increment:
0.1
Unit:
[%]
PID-configuration
Use:
This parameter determines if the controller is operated as PI- or as
PID- controller. If it is operated as PI-controller, the parameters
Derivative D0...D3
are ineffective.
Range:
PI,
PID
Default:
PI