Operating Manual BMGZ710 and BMGZ710.PNET
20.04.2021
18
Operating parameters
Name
Description
Scaling output
Here, you can define the flow rate that generates the
maximum output signal (10 V or 20 mA) at the analogue
outputs.
The resolution is 12 bits.
Unit t/h
Min. 1.0
Max. 5000.0
Default 1000.0
Increment 0.1
Max. Q
The maximum flow rate Q of the conveyor belt scales is saved
under this parameter. If the flow rate falls below 5% of this
parameter, the counters stop integrating.
The measurement
is stopped, and an error is displayed.
Unit t/h
Min. 0
Max. 5000
Default 0
Increment 1
v-detection
If this parameter is set to “automatic”, the speed of the
conveyor belt is recorded with the pulse generator integrated
into the measuring roller.
If the parameter is set to “none”, no speed detection is
performed. The flow rate is then calculated with a fixed speed
of 1.00 m/s.
The digital input “belt running” is used to determine whether
the belt is stopped or running.
Unit -
Selection none
automatic
Default none
Table 4: Description of operating parameters