Operating Manual BMGZ710 and BMGZ710.PNET
20.04.2021
16
Parameter
Name
Description
Nominal force
Nominal force of the force senors. This value is indicated on
the label of the measuring roller and the labels of each force
sensor.
See measuring roller nameplate.
Unit N
Min. 1
Max. 5000
Default 1000
Increment 1
Table 2: Description of plant parameters
6.2
Operating parameters
Operating parameters
Parameter Unit
Selection
Default
Min.
Max. No.
Pulse output
[kg]
1, 10, 100,
1000
100
50
Current output
0 to 20; 4 to
20 mA
4 to 20 mA
51
Filter output
[Hz]
10.0
0.1
20.0
52
Scaling
[t/h]
1000.0
1.0
5000.0
53
Max. Q
[t/h]
0
1
5000
54
v-detection
- auto,
none
auto
55
Table 3: Operating parameters