Parameter
Name
Description
Belt length
The unrolled length of the conveyor belt is saved under this
parameter. This value is required for taring.
Unit m
Min. 1
Max. 5000
Default 10
Increment 1
Diameter
The diameter of the centre roller is saved under this parameter
(see measuring roller nameplate).
Unit mm
Min. 10
Max. 1000
Default 108
Increment 1
Pulse
The number of blades of the pulse generator is stored under
this parameter, see measuring roller nameplate. This value
corresponds to the number of pulses per revolution of the
measuring roller.
Unit -
Min. 1
Max. 100
Default 4
Increment 1
Distance
The distance between adjacent idlers is saved under this
parameter. This value corresponds to the sum of the distances
between the measuring roller and the preceding and following
idler stations.
Unit mm
Min. 100
Max. 5000
Default 2000