Operating Manual BMGZ710 and BMGZ710.PNET
20.04.2021
8
Illustration 5: BMGZ710.K Cabinet
BMGZ700_BA_Manual.ai
-
The cabinet is screwed on through the 4 holes in the back wall
-
Use the rubber mounts if the system experiences vibrations
4.1
Electrical connection (see installation instructions for the FMS
measuring roller)
The connection between the measuring roller and the evaluation unit must use the 8-
core twisted-pair cable (min. 4x2x0.75 mm
2
) provided.
The cable must be laid away from any power cables to ensure that no interference is
induced in the measurement signal. On the measuring roller side, remove the plastic
sheath of the cable over a length of approx. 14 cm.
The white wire is not required. Connect the shield to terminal 5.
On the evaluation unit side, remove the plastic sheath over a length of a approx. 25-54
cm. The white wire is not required.
The cable shield must be connected on both sides.
For the K version of the housing (cabinet), feed the cable with the 8-pin plug through the
cabinet wall.
Illustration 6: Connection cable, evaluation unit side
BMGZ700_BA_Manual.ai