background image

 

 

PRODUCT 
FEATURES

 

 
OPERATION 

 
This firebox is designed for use with 
approved ANS Z21.11.2 decorative 
type unvented multi-sided room 
heaters. (Physical size limitations 
apply. Refer to minimum firebox 
requirements supplied with log heater.) 
The maximum size log this firebox will 
accept is: width of 32”, depth of 19” 
and height of 17”. 
 
This firebox requires no outside venting 
or chimney making installation easy 
and inexpensive. When used without 
the blower, the firebox requires no 
electricity making it ideal for 
emergency back-up heat. 
 

BLOWER ACCESSORY 

 
The firebox will accept the CBKUVPN 
accessory. The variable blower allows 
you to select the fan speed you desire. 
The blower circulates heat air from the 
firebox into the room. Use of blower is 
optional. 
 

BRICK LINER 

 
This firebox features a concrete brick 
liner. As with all concrete liners, this 
liner may develop slight cracks when 
exposed to heat. These cracks will not 
affect the performance of the firebox or 
vent-free gas logs.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

PRODUCT 
SPECIFICATIONS 

         OWNER’S 

MANUAL 

 

 
FIGURE 1-PENINSULA (THREE-SIDED) FIREBOX 

 

D1116 

Содержание FGPN

Страница 1: ...ly call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a...

Страница 2: ...n hot for a time after shutdown Allow surfaces to cool before touching 13 Carefully supervise young children when they are in the same room with the firebox 14 Turn the firebox off and let cool before...

Страница 3: ...d without the blower the firebox requires no electricity making it ideal for emergency back up heat BLOWER ACCESSORY The firebox will accept the CBKUVPN accessory The variable blower allows you to sel...

Страница 4: ...fy your space provide adequate ventilation Unusually Tight Construction The air that leaks around door and windows may provide enough fresh air for combustion and ventilation However in buildings of u...

Страница 5: ...Total 79 000 Btu Hr Do not include the direct vent gas appliances Direct Vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with...

Страница 6: ...ducts Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor Con...

Страница 7: ...the floor is 0 inches E Clearances from the open end of the firebox to the facing wall should not be less than 36 inches Minimum clearances to combustible are Back of outer casing 0 min Drywall to sid...

Страница 8: ...rances shown in Figure 7 Follow the instructions below to install the firebox in this manner 1 Frame in rough opening The firebox framing should be constructed of 2 x 4 lumber or heavier Construct fra...

Страница 9: ...rebox combustible materials such as wall board gypsum board sheet rock drywall plywood etc may be butted up next to the side and top of the firebox Combustible materials should never overlap the fireb...

Страница 10: ...coming NPT black iron gas line You may also route the eincoming NPT black iron gas line directly to the appliance regulator Remove the gas line cover plate from the vent free firebox s outer surround...

Страница 11: ...ing provided see Figure 15 The receptacle may be relocated to either side when necessary However the cover plate must be replaced over the unused access point Be certain to properly ground the vent fr...

Страница 12: ...erly 5 Apply gentle force between hook and loop mounting strips to seat blower 6 Remove control knob and lock nut from blower speed control shaft 7 Place the speed control shaft through 3 8 hole provi...

Страница 13: ...alter the setting on the pilot assembly See the operating instructions supplied with your vent free log heater for additional cleaning instructions IMPORTANT Turn off the gas supply at the external s...

Страница 14: ...rn the defective part to the factory PART NOT UNDER WARRANTY Contact authorized dealer of this product If they can t supply original replacement part s call Fireplace Manufacturer s Part Department at...

Страница 15: ...t circulation and may be be installed during or after firebox installation POLISHED BRASS HOOD FGA6017 For End 02240 FGA6054 For Sides 02239 Replaces the standard black hoods to provide a more formal...

Страница 16: ...15 ILLUSTRATED PARTS BREAKDOWN Model FGPN UNVENTED VENT FREE FIREBOX...

Страница 17: ...de Refractory Retainer 2 9 12125 Screen 4 10 26752 Louver Assy Black 2 11 26733 Lower Door Panel 2 12 14200 Receptacle 1 13 21171 Access Hole Cover 3 14 12126 Screen 1 15 26771 Louver Assy End 1 16 11...

Страница 18: ...BURNING CONVENTIONAL FIREPLACE FUELS SUCH AS WOOD COAL OR ANY OTHER SOLID FUEL WILL CAUSE DAMAGE TO THE GAS APPLIANCE WILL PRODUCE EXCESSIVE TEMPERATURES AND WILL RESULT IN A FIRE HAZARD LIMITATION OF...

Отзывы: