manualshive.com logo in svg
background image

SAVE THIS BOOK

This book is valuable. In addition to instructing you 

on how to install and maintain your appliance, it also 

contains information that will enable you to obtain re-

placement parts or accessory items when needed. Keep 

it with your other important papers.

This fireplace is approved for use as a wood burning 

fireplace or for use with a vented gas log approved to 

ANS Z21.60, Z21.84 standards or for use with a vent-free 

gas log heater approved to ANS Z21.11.2 standard. A FMI 

PRODUCTS, LLC hood must be installed when using a 

vent-free log heater (see , page 16).

This  wood  burning  fireplace  complies  with  UL127-

CAN/ULC-S610-M87  standard  as  a  FACTORY  BUILT 

APPLIANCE.

FOR CANADA: The authority having jurisdiction (such 

as the municipal building department, fire department, 

etc.) should be contacted before installation to deter-

mine the need to obtain a permit.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

RESIDENTIAL AND OUTDOOR WOOD BURNING FIREPLACE

OWNER’S OPERATION AND INSTALLATION MANUAL

MODELS (V)S42 SERIES

For more information, visit www.fmiproducts.com

PFS

®

US

C

ICC-ES #ESR-2542

Содержание (V)S42 SERIES

Страница 1: ... 2 standard AFMI PRODUCTS LLC hood must be installed when using a vent free log heater see page 16 This wood burning fireplace complies with UL127 CAN ULC S610 M87 standard as a FACTORY BUILT APPLIANCE FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to deter mine the need to obtain a permit INSTALLER...

Страница 2: ...ydamageor loss of life Refer to this manual for assistance or additional in formation Consult a qualified installer or local distributor IMPORTANT Check local codes before installing this fireplace Before beginning the installation of the fireplace read these instructions through completely This FMI PRODUCTS LLC fireplace and its components are safe when installed according to this installation ma...

Страница 3: ... NOT LESS THAN 12 1 AIRSPACE TO COMBUSTIBLE COMBUSTIBLE WALL BOARD 0 TO MATERIAL NO COMBUSTIBLE MATERIAL ON FACE SIDEWALL TERMINATION SQUARE CHASE TOP GAS LINE KNOCK OUT AIR KIT KNOCK OUTS ROUND TOP TERMINATION GAS LINE KNOCK OUTS ELECTRICAL OUTLET LEFT SIDE RIGHT SIDE 8 125 12 625 14 25 45 25 41 48 42 24 8 39 16 25 29 5 2 5 10 625 1 12 2 5 8 125 6 75 10 625 12 25 48 0 625 36 22 5 ...

Страница 4: ...etermine the safest and most efficient location for the fireplace you must take into consideration the following guidelines 1 The location must allow for proper clear ances see Figures 1 and 2 2 Consider a location where the fireplace will not be affected by drafts air condition ing ducts windows or doors 3 A location that avoids the cutting of joists or roof rafters will make installation easier ...

Страница 5: ...means to prevent the hearth extension from shifting and seal gap between the fireplace frame and hearth extension with a noncom bustible material see Figure 3 FIREPLACE INSTALLATION Figure 3 Hearth Extension Seal Gap Fireplace Front Ember Protector Fireplace Front Raised Hearth Fireplace Front Elevated Ember Protector Ember Protector Seal Gap Hearth Extension WARNING Hearthextension is to be insta...

Страница 6: ...nd up Press down on each pipe section until lances securely engage hem on fireplace starter The wire will assure the proper spacing between inner and outer pipe sections VENTING INSTALLATION OPTIONAL OUTSIDE AIR KIT MODEL AK4 AK4F The installation of an outside air kit should be performed during the rough framing of the fireplace due to the nature of it s location Outside combustion air is accesse...

Страница 7: ... pipe between supports return elbow or 12S 8DM is 6 of angle run Maximum of two 6 angle run sections per chimney system see Figure 7 4 All pipe connections between the offset and return must be secured with two screws on the outer pipe only see Figure 9 page 8 Do not penetrate the inner stainless OFFSET RISE CHIMNEY LENGTH A B 48 36 24 18 12 4 3 8 16 3 8 ELBOW SET ONLY 9 3 4 25 1 2 1 12 3 4 30 3 4...

Страница 8: ...ews or Staples Min of 8 PENETRATING ROOF To maintain a 1 clearance to the pipe on a roof with a pitch a rectangular opening must be cut 1 Determine the center point through which the pipe will penetrate the roof 2 Determine the center point of the roof Pitch is the distance the roof drops over a given span usually 12 A 6 12 pitch means that the roof drops 6 for each 12 one measure horizontally dow...

Страница 9: ...torm Collar Flashing Cone Underlap Shingles at Bottom Overlap Shingles Top and Sides Only Figure 13 Flashing Installation Storm Collar Installation SC1 or SC2 Place storm collar over pipe and slide down until it is snug against the open edge of the flashing see Figure 14 Use SC1 for all round terminations and SC2 for all terminations with slip sections Apply waterproof caulk around the perimeter o...

Страница 10: ...e 16 Note If a decorative shroud is to be installed contact the manufacturer for specifications 10 FOOT RULE All flue gas outlet chimney terminations must extend a minimum of 3 feet in height above the highest point where it passes through the roof and must be at least 2 feet above the high est point of the roof that is within a horizontal distance of 10 feet see Figure 17 24 Min 24 Min 18 Min Typ...

Страница 11: ...T MAX HEIGHT 14 5 FT MIN HEIGHT OF 22 FT WITH 2 ELBOW SETS MAX HEIGHT OF 50 FT MAX HEIGHT 50 FT ANY SYSTEM 30E 8DM Figure 18 Typical Residential Installations Gas line hook up should be done by your supplier or a qualified service person Note Before you proceed make sure your gas supply is turned off Use only a 1 2 black iron pipe and appropri ate fittings 1 Remove knockout indentation on refrac t...

Страница 12: ...ed End for Fitting Connection Figure 20 Gas Line Installation WARNING Do not oper ate an unvented gas log set in this fireplace with the chimney removed If you install a decorative gas appliance vented gas log the decorative gas appliance must comply with the Standard for Decorative Gas Appliance for Installation in Solid Fuel Burning Fireplaces ANSZ21 60orZ21 84andshallalso beinstalledinaccordanc...

Страница 13: ...uch materials as pitch wax laden logs very dry mill end lumber and large amounts of paper or cardboard boxes can create an excessively hot fire and should not be burned in this fireplace Always keep the fire well back from the doors and never allow flames to contact the glass WARNING Fireplaces equipped with glass doors should be operated only with doorsfullyopenedordoorsfully closed Doors ifleftp...

Страница 14: ...ushing the handle in will lock the door closed WARNING Risk of fire Re placegratewithFMIPRODUCTS LLC model 111100 01 only This gratehasbeendesignedtokeep the operation of your fireplace safe and efficient LOCATING ACCESS COVER PLATE Sheet metal cover plates located underneath fronthearthrefractorymayhaveshiftedormoved out of place while fireplace was in transit These cover plates must be kept in t...

Страница 15: ...fractory Smooth White Brick 1 108170 01 Right Refractory Smooth White Herringbone 1 11 107816 03 Rear Refractory Textured White Brick 1 108171 03 Rear Refractory Textured White Herringbone 1 107816 02 Rear Refractory Textured Red Brick 1 108171 02 Rear Refractory Textured Red Herringbone 1 107816 01 Rear Refractory Smooth White Brick 1 108171 01 Rear Refractory Smooth White Herringbone 1 12 111091...

Страница 16: ...ts com 111099 01L 16 PARTS WOOD BURNING FIREPLACE MODELS S42 S42H S42R S42RH VS42 VS42H VS42R AND VS42RH 9 26 16 33 27 16 27 4 32 34 19 12 25 20 30 17 8 1 5 21 2 35 18 11 14 3 13 22 10 6 31 7 37 38 36 28 29 24 23 15 ...

Страница 17: ...ace Weldment 1 20 110892 02 Air Deflector 1 21 111327 02 Fireplace Top Insulation 1 22 Access Panel 1 23 107854 01 Right Refractory Bracket 1 24 107854 02 Left Refractory Bracket 1 25 111100 01 Grate 1 26 11418 Push On Nut 2 27 110891 01 Stainless Screen 2 28 Collar Insulation 1 29 20023 Chimney Starter Collar 1 30 20027 Refractory Retainer 2 31 106539 02 Grate Retainer 2 32 111073 01 Door Stop 1 ...

Страница 18: ... FLASHING 0 TO 6 12 PITCH V6F 8DM 6 12 TO 12 12 PITCH V12F 8DM ANTI DRAFT SHIELD Round Top Termination Only ADS 8DM HOOD STAINLESS STEEL HS42 Required when installing a vent free gas log in this fireplace BI FOLD GLASS DOOR BDO42 Black BDO42B Brushed Brass BDO42P Platinum 30 OFFSET AND RETURN 30E 8DM FIRESTOP SPACER FS 8DM DRAIN PAN DP42 ...

Страница 19: ...L INSTALLATION AK4 OUTSIDE AIR KIT FOR FLOOR INSTALLATION AK4F SQUARE CHASE TOP TERMINATION ET 8DM ETO 8DM ECONO TOP TERMINATION WITH SLIP SECTION ETL 8DM ETLO 8DM MESH ROUND TOP TERMINATIONS RT 8DM MESH ROUND TOP TERMINATIONS WITH SLIP SECTION RTT 8DM ROUND TOP TERMINATIONS WITH LOUVERS RTL 8DM ROUND TOP TERMINATIONS WITH LOUVERS WITH SLIP SECTION RTTL 8DM ...

Страница 20: ...www fmiproducts com 111099 01L 20 111099 01 Rev L 03 11 2701 S Harbor Blvd Santa Ana CA 92704 1 866 328 4537 www fmiproducts com ...