11
INSTALLATION
Continued
OPTIONAL BLOWER
ASSEMBLY INSTALLATION
Proper installation of the blower system
is required to insure that the maximum
discharge of air can be delivered through
the louvers on each side of the fireplace
for better access.
NOTE: You may perform this
installation from either side of the
fireplace. The lower door panels are
removable from both sides of the firebox
for better access.
1. Remove the blower assembly from
the packaging and inspect the fan and
wiring for damage. If any wiring is loose
or damaged, return the assembly for
exchange to your dealer or distributor.
2. Remove the 2 screws located at the
top of the lower door panel. Slide door
panel forward and up to remove tabs on
panel from locating slots in firebox (see
Figure 16).
3. Locate the two strips of hook and
loop mounting strips on one side of the
base of the lower compartment. Align
the mounting strips on blower with
mounting strips on base of firebox.
4. Install blower housing with exhaust
outlet ports directed upwards along inner
side wall of lower compartment. The
blower outlets must be installed flush to
the outer cabinet for air to flow properly.
5. Apply gentle force between hook
and loop mounting strips to seat blower.
6. Remove control knob and lock nut
from blower speed control shaft.
7. Place the speed control shaft
through 3/8” hole provided in right side
of lower door panel removed in Step 2.
8. While supporting speed control
housing, secure shaft in panel hole with
lock nut. Place control knob on shaft.
9. Plug blower power cord into
receptacle located in lower firebox
compartment. Check to make sure there
are no foreign objects in blower wheel.
10. Turn blower on and check for
proper operation.
11. Turn blower off before continuing.
12. Replace lower door panel by
inserting tabs on bottom of panel into
locating slots on firebox. Push door
panel into an upright position and secure
with screws removed in step 2.
Operating Optional Blower
CBKUVPN
Light your gas appliance with the blower
off. After about 10 minutes, turn the
blower on to deliver heated air at the top
louvers. The blower features a variable
control which, allows you to select the
blower speed you desire.
NOTE:
Periodically check the louvers
of the firebox and remove any dust, dirt
or obstructions.
UNVENTED (VENT-FREE) FIREBOX
WARNING: Never touch
the blower wheel while in
operation.
D1132
FIGURE 16-
Removing Lower Door Panel
FIGURE 17-
Optional Blower Wiring Diagram
D1133
D1131
FIGURE 18-
Installing Optional Blower