10
INSTALLATION
Continued
GAS SUPPLY TESTING
NOTE:
This section is intended as guide
for qualified technicians installing gas to
this vent-free firebox.
The appliance and it’s individual shut-
off valve must be disconnected from the
gas supply piping system during any
pressure testing of that system at test
pressure in excess of ½ psig (3.5 kPa).
The appliance must be isolated from the
gas supply piping system by closing its
individual manual shut-off valve during
any pressure testing of the gas supply
piping system at test pressures equal to
or less than 1/2 psig (3.5kPa).
HARD-WIRING FIREBOX
Model FGPN can be hard-wired to the
duplex outlet located inside the firebox
bottom if desired. This allows the blower
accessory to be plugged into the duplex
outlet.
ELECTRICAL
INSTALLATION
A model CBKUVPN blower system
assembly is available for use with the
FGPN vent-free firebox as an optional
accessory. This blower is designed to be
installed on the wall side of the FGPN
firebox, when provisions for a 120 VAC
supply connection are made at the end of
the cabinet. Use of a blower system other
than those manufactured by Fireplace
Manufacturer Incorporation voids the
warranty.
Electrical connections are made within
the receptacle with wires that are routed
through the bushing provided (see Figure
15). The receptacle may be relocated to
either side, when necessary. However,
the cover plate must be replaced over the
unused access point. Be certain to
properly ground the vent-free firebox
using the green grounding wire (see
Figure 17 on page 11).
NOTE: A 120V-supply connection to the
leads to the receptacle must be provided
for use with the optional blower kit
whether installed during or after initial
firebox installation. You may not be able
to install a supply connection after the
installation is completed. Refer to
Optional Blower Assembly Installation
on page 12 for specifics.
OWNER’S
MANUAL
WARNING: All gas
piping and connections must
be tested for leaks after the
installation is completed.
After ensuring that the
manual shut-off gas valve is
open, apply a soap and water
solution to all connections
and
joints. If bubbles
appear, leaks can be detected
and corrected. DO NOT USE
OPEN FLAME FOR LEAK
TESTING AND DO NOT
OPERATE ANY
APPLIANCE IF A LEAK IS
DETECTED.
CAUTION: Do not
connect vent-free heater
before pressure testing gas
piping. Damage to gas valve
may result and an unsafe
condition may be caused.
NOTICE: A qualified
electrician must connect
electrical wiring to duplex
outlet for built-in
installation. Follow all local
codes. In absence of local
codes follow The National
Electric Code ANS/NFPA
70.
D1129
FIGURE 14-
Sediment Trap Installation
FIGURE 15-
Locating Electrical
Connection and Gas Connection on
Wall Side of Fireplace
D1130