8X5 and 9X5 drive units
6
7
8
2
3
4
5
1
WS000630A
1.
Vibration – VIS 10
2.
Leakage in the junction box – FLS, Float Switch Leakage Sensor
3.
Stator winding temperature
4.
Main bearing temperature – Pt100 analogue temperature sensor
5.
Leakage in the stator housing – FLS
6.
Water in oil
(standard drive units only)
– CLS, Capacitive Leakage Sensor
7.
Support bearing temperature – Pt100 analogue temperature sensor
8.
Pump memory
Temperature sensors
Table 3: Thermal switch
Description
Measured value
Fault values
The thermal switch
is a normally closed
contact.
0-3 ohm, unless the wires are very long.
An infinite value (open circuit) indicates
either high temperature or a fault (a wire
is broken or there is a bad contact in a
connector).
Product Description
C3300/6x5, C/R3231, C3240, C3306, C3312, C3351, C3356, C3400, C3501, C3531, C3602, C3800 Installation,
Operation and Maintenance Manual
29
Содержание C/R3231
Страница 2: ...End of Disclaimer text ...