C3531 Motor rating and performance, 50 Hz
Low voltage
Table 57: C3531, 50 Hz, low voltage
Curve /
impeller
no.
Rotations
per minute
Drive unit Voltage, V
Rated
power, kW
Rated
current, A
Starting
current, A
Power
factor cos φ
1440
415
705 / 715
400
40
115
345
0.60
735 / 745
400
60
167
475
0.62
765 / 775
400
70
195
575
0.61
1240
490
705 / 715
400
40
110
390
0.59
735 / 745
400
60
158
550
0.61
765 / 775
400
80
207
710
0.62
805 / 815
400
100
256
1025
0.61
835 / 845
400
140
360
1455
0.61
1040
585
705 / 715
400
60
138
520
0.74
735 / 745
400
90
222
880
0.68
765 / 775
400
110
230
920
0.73
805 / 815
400
125
275
1170
0.75
835 / 845
400
170
380
1800
0.73
865 / 875
400
215
460
1915
0.76
840
735
735 / 745
400
125
245
1065
0.81
805 / 815
400
160
305
1360
0.81
835 / 845
400
215
460
2385
0.77
865 / 875
400
275
535
2730
0.79
905 / 915
400
340
610
3295
0.84
935 / 945
400
400
730
4510
0.82
640
990
835 / 845
400
250
475
2495
0.84
865 / 875
400
310
575
3370
0.82
905 / 915
400
375
700
3935
0.85
935 / 945
400
460
855
4880
0.85
935 / 945
400
560
1025
5250
0.87
965 / 975
400
680
960
5920
0.85