• 10 mm hexagon bit adapter with an extension of at least 125 mm (4.92 in.)
• Impeller puller
If applicable, contact your local sales and service representative for correct type and
size.
• Two crowbars, if applicable
CAUTION: Cutting Hazard
Worn parts can have sharp edges. Wear protective clothing.
NOTICE:
When laying the pump on its side, do not allow the weight of the pump to rest on any
portion of the impeller. The impeller must not be allowed to make contact with the
concrete floor or other hard and rough surfaces.
If you fail with the impeller installation, then you must redo the installation procedure from
the beginning.
Replace the C- or D-impeller
WS003639A
Figure 10: C-impeller
WS003640A
Figure 11: D-impeller
Remove the impeller: C, D
CAUTION: Cutting Hazard
Worn parts can have sharp edges. Wear protective clothing.
1. Remove the pump housing or the suction cover.
2. Remove the impeller screw.
If applicable, use the rod.
Maintenance
Flygt 3126.290 Installation, Operation, and Maintenance Manual
35