WS008385A
Figure 4: T-installation
These items are required:
• Anchor bolts for anchoring the pump to a base.
• Shut-off valves that allow you to remove the pump from service
NOTICE:
The risk of freezing is particularly high in T- or Z-installations.
1. Fasten the pump:
a) Bolt the stationary suction connection to the concrete base.
b) Bolt the pump to the suction connection.
2. Make sure that the pump is vertical.
3. Connect the suction line and discharge line.
4. Connect the motor cable and the starter and monitoring equipment according to the
separate instructions.
Make sure that the impeller rotation is correct. For more information, see
Check the
impeller rotation
(page 27)
5. Make sure that the weight of the pump does not put strain on the piping.
Make the electrical connections
General precautions
DANGER: Electrical Hazard
Before starting work on the unit, make sure that the unit and the control panel are isolated
from the power supply and cannot be energized. This applies to the control circuit as well.
WARNING: Electrical Hazard
Risk of electrical shock or burn. A certified electrician must supervise all electrical work.
Comply with all local codes and regulations.
Installation
20
Flygt 3126.290 Installation, Operation, and Maintenance Manual