Screws and nuts
Table 1: Stainless steel, A2 and A4, torque Nm (ft-lbs)
Property
class
M4
M5
M6
M8
M10
M12
M16
M20
M24
M30
50
1.0 (0.74)
2.0 (1.5)
3.0 (2.2)
8.0 (5.9)
15 (11)
27 (20)
65 (48)
127 (93.7) 220 (162) 434 (320)
70, 80
2.7 (2)
5.4 (4)
9.0 (6.6)
22 (16)
44 (32)
76 (56)
187 (138) 364 (268) 629 (464) 1240 (915)
100
4.1 (3)
8.1 (6)
14 (10)
34 (25)
66 (49)
115 (84.8) 248 (183) 481 (355) —
—
Table 2: Steel, torque Nm (ft-lbs)
Property
class
M4
M5
M6
M8
M10
M12
M16
M20
M24
M30
8.8
2.9 (2.1)
5.7 (4.2)
9.8 (7.2)
24 (18)
47 (35)
81(60)
194 (143) 385 (285) 665 (490) 1310
(966.2)
10.9
4.0 (2.9)
8.1 (6)
14 (10)
33 (24)
65 (48)
114 (84)
277 (204) 541 (399) 935 (689) 1840
(1357)
12.9
4.9 (3.6)
9.7 (7.2)
17 (13)
40 (30)
79 (58)
136 (100) 333 (245) 649 (480) 1120
(825.1)
2210
(1630)
Hexagon screws with countersunk heads
For hexagon socket head screws with countersunk head, maximum torque for all property
classes must be 80% of the values for property class 8.8 above.
Change the oil
The following items are needed for this procedure:
• New oil plugs
• New O-rings
• Oil that should be a medical white oil of paraffin type that fulfills FDA 172.878 (a) and
viscosity close to VG32.
1. Place the pump in a horizontal position.
2. Turn the pump so that the oil hole faces downwards.
3. Unscrew the oil plug.
If the pump has a hole with the markings "oil out" it is important that this hole is used
for drainage.
CAUTION: Compressed Gas Hazard
Air inside the chamber may cause parts or liquid to be propelled with
force. Be careful when opening. Hold a rag over the plug to prevent
liquid from spraying out.