867B,863
Service Manual
1-12
Frequency
AC Sensitivity
AC Volts
AC Current
Frequency
Sine Wave
Level
Frequency
Ranges
Sine Wave
Level
2 Hz - 500 kHz
60 mV rms
5 Hz - 30 kHz
300
µ
A - 300 mA
20% of range
500 kHz - 1 MHz
100 mV rms
5 Hz - 2 kHz
3A
300 mA
1 MHz - 2 MHz*
1V rms
5 Hz - 2 kHz
10A
3A
* Use single trigger mode for inputs above 1 MHz.
Accuracy
[
±
(percent of r counts)]
Range
Resolution
Accuracy
1000.00 Hz
0.01 Hz
0.05% + 2
10.0000 kHz
0.1 Hz
0.05% + 1
100.000 kHz
1 Hz
0.05% + 1
1.00000 MHz
10 Hz
0.05% + 1
2.0000 MHz
100 Hz
0.05% + 1
Duty Cycle
Range:
0.1% to 99.9%
Accuracy:
±
(5.2% divided by the pulse width in micros 2 counts) (1 ms = 1000 microseconds).
Period
Ranges:
999.99
µ
s, 9.999 ms, 99.99 ms, and 999 ms
Accuracy:
±
(0.05% of r 2 counts)
Pulse Width
Ranges:
999.99
µ
s, 9.999 ms, 99.99 ms, and 999 ms
Accuracy:
±
(5.2% divided by the pulse width in micros 2 counts) (1 ms = 1000 microseconds).
Содержание 863
Страница 49: ...Maintenance Disassembly 3 3 5 OFF 1 6 Places 4 5 5 3 3 2 os5f eps Figure 3 1 Disassembly ...
Страница 50: ...867B 863 Service Manual 3 6 os6f eps Figure 3 1 Disassembly cont ...
Страница 52: ...867B 863 Service Manual 3 8 5 1 6 2 3 4 os30f eps Figure 3 2 Reassembly ...
Страница 94: ...List of Replaceable Parts Parts 5 5 15 FLUKE 86X 4001 Sheet 1 of 2 os31_1f eps Figure 5 2 A1 Main PCA ...
Страница 95: ...867B 863 Service Manual 5 16 FLUKE 86X 4001 Sheet 2 of 2 os31_2f eps Figure 5 2 A1 Main PCA cont ...
Страница 96: ...6 1 Chapter 6 Schematic Diagrams Title Page 6 1 A1 Main PCA Assembly 6 3 ...
Страница 98: ...867B 863 Service Manual 6 4 FLUKE 867 1001 Sheet 2 of 5 Figure 6 1 A1 Main PCA cont ...
Страница 99: ...Schematic Diagrams 6 6 5 FLUKE 867 1001 Sheet 3 of 5 Figure 6 1 A1 Main PCA cont ...
Страница 100: ...867B 863 Service Manual 6 6 FLUKE 867 1001 Sheet 4 of 5 Figure 6 1 A1 Main PCA cont ...
Страница 101: ...Schematic Diagrams 6 6 7 FLUKE 867 1001 Sheet 5 of 5 Figure 6 1 A1 Main PCA cont ...