867B,863
Service Manual
1-10
Diode Test (Manual)
Range:
3V
Resolution:
0.0001V
Accuracy:
±
0.05% of r 2 digits
Open Circuit Voltage
: 3.1V
Diode Test (Auto)
Accuracy:
20%
Current Ranges
Ranges for True
RMS AC Current
and DC Current
True RMS
Measurement Range
(% Range to % Full
Scale)
Ranges for Average
Responding AC
Current
Maximum
Burden
Voltage
Fuse
Protection
300.00
µ
A
1
5% - 100%
300.0
µ
A
0.03V
440 mA @
1000V
3000.0
µ
A
1
5% - 100%
3000
µ
A
0.3V
440 mA @
1000V
30.000 mA
5% - 100%
30.00 mA
0.03V
440 mA @
1000V
300.00 mA
5% - 100%
300.0 mA
0.3V
440 mA @
1000V
3.0000A
5% - 100%
3.000A
0.1V
11A @
1000V
10.000A
5% - 100%
10.00A
0.3V
11A @
1000V
1. DC ranges available on the Fluke 867B only.
DC Current Accuracy [
±
(percent of r counts)]
Range
Resolution
Accuracy
300
µ
A
1
0.01
µ
A
0.1% + 15
3000
µ
A
1
0.1
µ
A
0.1% + 2
30 mA
2
1
µ
A
0.05% + 15
300 mA
10
µ
A
0.1% + 2
3A
100
µ
A
0.2% + 15
10A
1 mA
0.2% + 2
1. Ranges available on the Fluke 867B only.
2. Fluke 863 30 mA DC range accuracy 0.1% + 15.
AC Current Accuracy [
±
(percent of r counts)]
Range
Resolution
True RMS AC Current Accuracy
(Average AC counts)
2
True RMS
Avg.
20 Hz to
50 Hz
50 Hz to
3 kHz
3 kHz to
10 kHz
10 kHz to
30 kHz
300
µ
A
1
0.01
µ
A
0.1
µ
A
1% + 10
(4)
0.75% + 10
(4)
2% + 20
(4)
2% + 40
(4)
3000
µ
A
1
0.1
µ
A
1
µ
A
1% + 10
(4)
0.75% + 10
(4)
2% + 20
(4)
2% + 40
(4)
30 mA
1
µ
A
10
µ
A
1% + 10
(4)
0.75% + 10
(4)
2% + 20
(4)
2% + 40
(4)
300 mA
10
µ
A
100
µ
A
1% + 10
(4)
0.75% + 10
(4)
2% + 20
(4)
NA
3A
100
µ
A
1 mA
1% + 10
(4)
0.75% + 10
(4)
NA
NA
10A
1 mA
10 mA
1% + 10
(4)
0.75% + 10
(4)
NA
NA
1. Ranges available on the Fluke 867B only.
2. Replace counts with Average AC counts for Average Responding AC measurements. In 300
µ
A
range, floor count increases to 20 with battery eliminator.
Содержание 863
Страница 49: ...Maintenance Disassembly 3 3 5 OFF 1 6 Places 4 5 5 3 3 2 os5f eps Figure 3 1 Disassembly ...
Страница 50: ...867B 863 Service Manual 3 6 os6f eps Figure 3 1 Disassembly cont ...
Страница 52: ...867B 863 Service Manual 3 8 5 1 6 2 3 4 os30f eps Figure 3 2 Reassembly ...
Страница 94: ...List of Replaceable Parts Parts 5 5 15 FLUKE 86X 4001 Sheet 1 of 2 os31_1f eps Figure 5 2 A1 Main PCA ...
Страница 95: ...867B 863 Service Manual 5 16 FLUKE 86X 4001 Sheet 2 of 2 os31_2f eps Figure 5 2 A1 Main PCA cont ...
Страница 96: ...6 1 Chapter 6 Schematic Diagrams Title Page 6 1 A1 Main PCA Assembly 6 3 ...
Страница 98: ...867B 863 Service Manual 6 4 FLUKE 867 1001 Sheet 2 of 5 Figure 6 1 A1 Main PCA cont ...
Страница 99: ...Schematic Diagrams 6 6 5 FLUKE 867 1001 Sheet 3 of 5 Figure 6 1 A1 Main PCA cont ...
Страница 100: ...867B 863 Service Manual 6 6 FLUKE 867 1001 Sheet 4 of 5 Figure 6 1 A1 Main PCA cont ...
Страница 101: ...Schematic Diagrams 6 6 7 FLUKE 867 1001 Sheet 5 of 5 Figure 6 1 A1 Main PCA cont ...