User Manual
E110-P
Page 16
FW_E110-P_M_v0301-01_EN
4. When the desired record is selected, press PROG-key again to review the details of the record.
Use the SELECT- and CLEAR-keys to scroll through the data in the record, indicated by a letter-
suffix behind the record number (for example 1234.A
à
1234.B
à
1234.C
à
1234.A).
TOTAL
LOG
GAL
0
00
1
10
30
20
80
90
70
LOG
0
00
1
10
30
20
80
90
70
Fig. 12:
Example of interval record 0003.B: Total (l) and event record 0128.A: Total Clear (r)
5. To leave the record details and return to the record selection list, press the PROG-key again.
6. To leave LOG-mode completely and return to OPERATOR-mode, press the PROG-key for 3
seconds or wait 3 minutes.
7. To select a different logbook, return to OPERATOR-mode and perform the procedure again.
The following table shows the available logbooks and record data in LOG-mode:
Logbook
Record data
INTERVAL
Recorded interval data (empty when none)
1234.A
Rate
1234.B
Total
1234.C
Accumulated total
DAILY
Recorded daily log data (empty when none)
1234.A
Rate
1234.B
Total
1234.C
Accumulated total
EVENTS
Recorded events (empty when none)
1234.A
Event name
1234.B
(if applicable for the event) Modbus register number
1234.C
(if applicable for the event) Old setting of the Modbus register number
1234.D
(if applicable for the event) New setting of the Modbus register number
Note: The 1234 in the above table represents the sequence number of the record.