![Flow 94K HYPERPRESSURE Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/flow/94k-hyperpressure/94k-hyperpressure_manual_2307763070.webp)
Location E
WATER LEAKAGE
Weep holes and locations are identified on the illustrations on Pages 64-65.
Fluid
Likely problem
Other possible symptoms
Maintenance
procedure
Kit or parts needed
Qty
.
Temp
.
Steam
with each
stroke
Hot/warm
Incorrect loading of
intensifier tie rods
Water leakage from A,B,C,D
A
—
High-pressure
cylinder failure
•
Pump cannot maintain pressure
•
Uneven intensifier stroking
A,C
High-pressure cylinder
020592-1
(2 per intensifier)
Seal carrier failure
•
Pump cannot maintain pressure
•
Uneven intensifier stroking
A,B
High-pressure seal
cartridge 052190-1 or
040015-1
(2 per intensifier)
Small drip
with each
stroke
Warm
High-pressure
seal leakage
Note: a small amount of leakage is normal during operation
High-pressure
cylinder failure
•
Pump cannot maintain pressure
•
Uneven intensifier stroking
A,C
High-pressure cylinder
020592-1
(2 per intensifier)
Seal carrier failure
•
Pump cannot maintain pressure
•
Uneven intensifier stroking
A,B
High-pressure seal
cartridge 052190-1 or
040015-1
(2 per intensifier)
Large flow
with each
stroke
Hot/warm
High-pressure
cylinder failure
•
Pump cannot maintain pressure
•
Uneven intensifier stroking
A,C
High-pressure cylinder
020592-1
(2 per intensifier)
Check valve
body failure
•
Pump cannot maintain pressure
•
Uneven intensifier stroking
A,B
High-pressure seal
cartridge 052190-1 or
040015-1
(2 per intensifier)
70 | M-376
© Flow International Corporation
94K HYPERPRESSURE INTENSIFIER
Содержание 94K HYPERPRESSURE
Страница 1: ...94K HYPERPRESSURE INTENSIFIER M 376 REV G JUNE 2012...
Страница 4: ...Notes 4 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 14: ...Replacement parts 14 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 16: ...Notes 16 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 30: ...Notes 30 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 36: ...Notes 36 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 46: ...Notes 46 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 62: ...Notes 62 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 64: ...64 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 65: ...Flow International Corporation M 376 65 CHAPTER 4 Troubleshooting...
Страница 78: ...020071 Check valve assembly 78 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...