Location D
WATER LEAKAGE
Weep holes and locations are identified on the illustrations on Pages 64-65.
Fluid
Likely problem
Other possible symptoms
Maintenance
procedure
Kit or parts needed
Qty
.
Temp
.
Steam
with each
stroke
Hot/warm
Incorrect loading of
intensifier tie rods
Water leakage from A,B,C,E
A
—
High-pressure
cylinder failure
•
Pump cannot maintain pressure
•
Uneven intensifier stroking
A,C
High-pressure cylinder
020592-1
(2 per intensifier)
Check valve
body failure
•
Pump cannot maintain pressure
•
Uneven intensifier stroking
A,D
Check valve assembly
020071-1
Large flow
with each
stroke
Hot/warm
High-pressure
cylinder failure
•
Pump cannot maintain pressure
•
Uneven intensifier stroking
A,C
High-pressure cylinder
020592-1
(2 per intensifier)
Check valve
body failure
•
Pump cannot maintain pressure
•
Uneven intensifier stroking
A,D
Check valve assembly
020071-1
Continuous
flow or
steady
drip
Cold
Incorrect loading of
intensifier tie rods
Leaks even when pump is stopped
and inlet water pressure exists
A
—
Debris between
sealing surfaces
Leaks even when pump is stopped
and inlet water pressure exists
A
—
© Flow International Corporation
M-376 | 69
CHAPTER 4
Troubleshooting
Содержание 94K HYPERPRESSURE
Страница 1: ...94K HYPERPRESSURE INTENSIFIER M 376 REV G JUNE 2012...
Страница 4: ...Notes 4 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 14: ...Replacement parts 14 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 16: ...Notes 16 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 30: ...Notes 30 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 36: ...Notes 36 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 46: ...Notes 46 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 62: ...Notes 62 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 64: ...64 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 65: ...Flow International Corporation M 376 65 CHAPTER 4 Troubleshooting...
Страница 78: ...020071 Check valve assembly 78 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...