48. Place the seal carrier assembly onto the plunger end,
then using the filler tube as a tool, push the assembly
along the plunger until it butts against the end bell
face.
49. Install the high-pressure cylinder by sliding it over the
ceramic plunger and into the end bell bushing.
A slight rocking motion will help ease the cylinder
into position
.
50. Install the filler tube in the high-pressure cylinder.
CAUTION
Make sure the filler tube is oriented correctly. There is
a wall inside the tube that must be at the outermost end
of the tube when it is inserted. Failure to orient the
tube correctly will damage the intensifier assembly.
51. Reinstall the check valve assembly and end cap by
sliding it along the tie rods and guiding the high-
pressure cylinder into the bronze bushing of the end
cap. Take care to align the check valve assembly with
the correct orientation as previously noted in Step 5.
52. Repeat Steps 48–51 at the other end of the
intensifier.
53. Reload the intensifier tie rods.
•
See
Maintenance Procedure A
, Assembling the
Intensifier
54. Reconnect the high-pressure tubing and the inlet
water hoses.
60 | M-376
© Flow International Corporation
94K HYPERPRESSURE INTENSIFIER
Содержание 94K HYPERPRESSURE
Страница 1: ...94K HYPERPRESSURE INTENSIFIER M 376 REV G JUNE 2012...
Страница 4: ...Notes 4 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 14: ...Replacement parts 14 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 16: ...Notes 16 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 30: ...Notes 30 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 36: ...Notes 36 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 46: ...Notes 46 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 62: ...Notes 62 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 64: ...64 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 65: ...Flow International Corporation M 376 65 CHAPTER 4 Troubleshooting...
Страница 78: ...020071 Check valve assembly 78 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...