Location G
WATER LEAKAGE
Weep holes and locations are identified on the illustrations on Pages 64-65.
Fluid
Likely problem
Other possible symptoms
Maintenance
procedure
Kit or parts
needed
Qty
.
Temp
.
Small drip
with each
stroke
Warm
Insufficient torque between high-
pressure gland and outlet adapter
•
Pump cannot maintain pressure
•
Uneven intensifier stroking
Refer to
Small High-Pressure
Components manual
Damaged cone on high-pressure
tubing
•
Pump cannot maintain pressure
•
Uneven intensifier stroking
High-pressure collar not threaded
far enough onto high-pressure
tubing
•
Pump cannot maintain pressure
•
Uneven intensifier stroking
High-pressure tubing not threaded
far enough along length of tubing
•
Pump cannot maintain pressure
•
Uneven intensifier stroking
High-pressure tubing failure or
failed outlet adapter
•
Pump cannot maintain pressure
•
Uneven intensifier stroking
Large flow
with each
stroke
Warm/hot
Insufficient torque between high-
pressure gland and outlet adapter
•
Pump cannot maintain pressure
•
Uneven intensifier stroking
Damaged cone on high-pressure
tubing
•
Pump cannot maintain pressure
•
Uneven intensifier stroking
High-pressure collar not threaded
far enough onto high-pressure
tubing
•
Pump cannot maintain pressure
•
Uneven intensifier stroking
High-pressure tubing not threaded
far enough along length of tubing
•
Pump cannot maintain pressure
•
Uneven intensifier stroking
High-pressure tubing failure or
failed outlet adapter
•
Pump cannot maintain pressure
•
Uneven intensifier stroking
72 | M-376
© Flow International Corporation
94K HYPERPRESSURE INTENSIFIER
Содержание 94K HYPERPRESSURE
Страница 1: ...94K HYPERPRESSURE INTENSIFIER M 376 REV G JUNE 2012...
Страница 4: ...Notes 4 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 14: ...Replacement parts 14 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 16: ...Notes 16 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 30: ...Notes 30 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 36: ...Notes 36 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 46: ...Notes 46 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 62: ...Notes 62 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 64: ...64 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...
Страница 65: ...Flow International Corporation M 376 65 CHAPTER 4 Troubleshooting...
Страница 78: ...020071 Check valve assembly 78 M 376 Flow International Corporation 94K HYPERPRESSURE INTENSIFIER...