![FLIR Ranger HRC MS Скачать руководство пользователя страница 234](http://html1.mh-extra.com/html/flir/ranger-hrc-ms/ranger-hrc-ms_operators-manual_2306230234.webp)
Ranger HRC™ operator´s manual – Technical appendices
Publ. No. TM 614 006 699 Rev B – ENGLISH (EN) – Oct 30. 2008
Trouble shooting guide
Symptom
Action
The video image is displayed, but the Pan/Tilt
unit does not operate after power on.
Press and hold down the
PRK
button for 3
seconds to activate the Pan/Tilt unit.
Pressing the buttons on the JCU does not give
the expected effect.
Check the JCU settings in the System Software;
for example, the
MMI Control mode
,
Nuc button
and
Left/Right scanpoint selection
features.
The TV image looks strange.
Check the TV settings in the System Software;
the
Back light comp
,
Image effect
and
Near IR
sensitive
features.