Ranger HRC™ operator´s manual – Hardware installation
120
Publ. No. TM 614 006 699 Rev B – ENGLISH (EN) – Oct 30. 2008
Alignment with LRF unit as reference
Step
Action
16
If the elevation alignment is not correct, as in Figure 9.12, adjust the position of the
camera according to the elevation adjustment procedure in section 9.3.4.2.
Repeated distance measurements and elevation adjustments may be needed before the
elevation alignment is correct.
17
Verify that the azimuth alignment is still correct. If not, repeat the distance measurements
from the sides and azimuth adjustment procedures followed by distance measurements
from above and elevation adjustments until the both the azimuth and elevation alignment
is correct.
18
The camera that has now been aligned is used as reference when aligning the other
camera, according to section 9.3.2.
Figure 9.11 Azimuth alignment not correct
Figure 9.12 Elevation alignment not correct