Manual MCS-64 Page 24
Index
Sub-
index
Name
Type
Attri-
bute
Default-value
Meaning
2C00 -
2C3F
for
LDM
0..63
0
1
2
3
4
5
Number of entries.
Mass Flow Control.
Mass Flow Status.
UI8
UI8
UI8
ro
rw
ro
2
Number of entries in the mass flow control words.
Mass Flow control word.
Mass Flow status/info word
2CFF
Number of entries.
As for 2C00-2C3F
UI8
I32
ro
wo
2
Number of entries in the mass flow control words.
As for 2C00 – 2C3F, except this is WRITE ONLY and the settings are
broadcasted to all LDMs.
6401
0
1
2
3
4
5
6
Number of entries
Gross weight
Net Weight
Tare
Dosed weight
Dosed tare
Average weight
UI8
I16
I16
I16
I16
I16
I16
ro
ro
ro
ro
ro
ro
ro
6
Number of entries in the 16 bit analog input module (PC6D only)
These entries are mandatory according to DS401. They are the same as for
index 6402, but shifted 8 bits to the right (value/256).
6402
0
1
2
3
4
5
6
7
Number of entries
Gross weight
Net Weight
Tare
Dosed weight
Dosed tare
Average weight
A/D sample
UI8
I32
I32
I32
I32
I32
I32
I32
ro
ro
ro
ro
ro
ro
ro
ro
7
Number of entries in the 32 bit analog input module (PC6D only)
These values are the internal long integer representation of the weight (the
integer values are multiplied by 10^dp [2300sub0B]).
Index 6402 is a sub-set of index 2001.
6403
0
1
2
3
4
5
6
Number of entries
Gross weight
Net Weight
Tare
Dosed weight
Dosed tare
Average weight
UI8
REAL32
REAL32
REAL32
REAL32
REAL32
REAL32
ro
ro
ro
ro
ro
ro
ro
6
Number of entries in the float analog input module (PC6D only)
These values are the floating-point representation of the weight as they are
transmitted in the PDO1(tx).
Index 6403 is a replica of index 2000.
Содержание MCS-64