The CANopen SDOs is a confirmed service, and overrun does not occur if the CAN controller
only communicates with the Gateway in the PRE-OPERATIONAL state. When a SDO has
been received by the controller no further communication takes place until the service has
been acknowledged (or a timeout occurs). However, other types of communication may fill
the Gateways internal buffer storage. In this event, the Gateway will issue an Overrun
Emergency message.
3.2 Communication
Profile
The parameters which are critical for communication are determined in the communication
profile.
This includes the data for manufacturer's product nomenclature, for identification, or the
parameters for object mapping.
Abbreviations used in Tables:
ro
read only
rw
read / write
wo
write only
(read will not be regarded as an error, but returns undefined results)
UI8
Unsigned8
UI16
Unsigned16
UI32
Unsigned32
I32
Signed32
REAL32
32 bit IEEE754 floating point
VS
Visible String
3.3 Object
Directory
The object directory of the CAN communication module is described below:
Please look the following pages.