4.6 Output
Commands
– GG, GN, GT, GS
The following commands “Get” the Gross, Net, Tare and ADC (Sample) values from the
LDM88.x are available on the CAN profile index 2000 and 2001 in floating point and integer
respectively.
GG
Get Gross value
[ 2000/2001sub01 ]
Normally sent in TPDO1, if selected by index 1A00sub01.
Master (PC / PLC) sends
Device responds
Result
GG G+01.100
Gros weight 1.100 d
GN
Get Net value
[ 2000/2001sub02 ]
Normally sent in TPDO1, if selected by index 1A00sub01.
Master (PC / PLC) sends
Device responds
Result
GN G+01.000
Net weight 1.000 d
GT
Get Tare value
[ 2000/2001sub03 ]
Master (PC / PLC) sends
Device responds
Result
GT T+00.100
Tare weight 100 d
GS
Get ADC Sample value
[ 2900sub07 ]
This command gets the actual Analogue to Digital Converter (ADC) value. This can be useful
during development or when calibrating to see how much of the ADC range is being used.
Master (PC / PLC) sends
Device responds
Result
GS S+125785
AD-value = 125.785 d
For service applications, it is helpful to note the GS values for the “no-load” or “zero” output
and when the “calibration load” is applied.