Manual MCS-64 Page 20
Index
Sub-
index
Name
Type
Attri-
bute
Default-value
Meaning
2400 -
243F
for
LDM
0..63
0
1
Number of entries
Dose Info
UI8
UI16
ro
ro
1
Read the dose info:
Bit value
Meaning
$0001
Coarse valve open
$0002
Fine valve open
$0004
Dose program running
$0008
Not used
$0010
Not used
$0020
Not used
$0040
Tare out of range – no filling in this cycle
$0080
Zero out of range
$FF00
The High byte has the following interpretation:
-
00= Idle
-
01= Waiting for trigger(2
nd
trigger)
-
02= Bottle on, calculating tare
-
03= Pre-fill
-
04= Main Filling
-
05= Fine Filling
-
06= In-flight delay
-
07= Post fill calculations
-
08= Post Filling