6 Installation
FLUXUS G809
6.2 Transducers
57
UMFLUXUS_G809V2-2EN, 2020-06-25
• Select the arrangement according to the measurement.
• Disassemble the transducer mounting fixture PermaFiX, see Fig. 6.53.
• Place one of the rails on the pipe, see Fig. 6.55.
• Insert the screws (M6) into the holes of the rail and secure them with nuts.
• Slide the second rail (arrangement a) or the counter plate (arrangements b, c, d) onto the screws on the opposite side of
the pipe and secure it with nuts.
• Make sure not to tilt the rails when tightening the nuts.
• Repeat the steps for the second rail, if necessary.
Installation of the rail with tension straps
The number and arrangement of PermaFiX rails depend on the required transducer arrangement and transducer distance.
See Fig. 6.56 for an overview of possible arrangements.
• Select the arrangement according to the measurement.
• Disassemble the transducer mounting fixture PermaFiX, see Fig. 6.53.
• Cut the tension strap to length (pipe circumf at least 120 mm).
Fig. 6.55: Installation of the rail with bolts (diagonal arrangement, small transducer distance)
1 – rail
2 – screws
3 – nuts
Fig. 6.56: Possible arrangements of PermaFiX (installation with tension straps)
a – diagonal arrangement, small transducer distance
b – reflection arrangement, small transducer distance
c – diagonal arrangement, large transducer distance
d – reflection arrangement, large transducer distance
2
1
3
a
c
b
d