A Menu Structure
144
UMFLUXUS_G8V4-6-1EN, 2018-10-10
input of the fixed upper limit of the sound speed
range: 0...3 000 m/s
0: the default limit of 1 848 m/s will be used
This display will only be indicated if the SuperUser mode is activated.
x
Input of the offset.
range: 0...900 m/s
0: the default limit of 300 m/s will be used
This display will only be indicated if the SuperUser mode is activated.
x
activation of the totalizers overflow
x
activation of the taking-over of the totalizer values after the measurement re-
start
x
input of a time interval after which the transmitter has to detect a long mea-
surement failure if there are no valid measured values
0: the default value of 30 s is used
This display will only be indicated if the SuperUser mode is activated.
x
input of the number of decimal places of the totalizers
Automatic
: dynamic adjustment
Fixed to x digit
: 0...4 decimal places
This display will only be indicated if the SuperUser mode is activated.
x
activation of the manual reset of the totalizers
This display will only be indicated if the SuperUser mode is activated.
x
activation of the display of the totalizer sum
This display will only be indicated if the SuperUser mode is activated.
x
activation of the display of the last valid measured value
This display will only be indicated if the SuperUser mode is activated.
x
activation of the turbulence mode
x
Special Funct.\SYSTEM settings\Measuring\Calibration
selection of the measuring channel whose flow parameters are to be defined
This display will only be indicated if the SuperUser mode is activated.
determination of the profile bounds
factory
: the default profile bounds will be used
user
: the profile bounds can be defined
This display will only be indicated if the SuperUser mode is activated.
Input of the max Reynolds number at which the flow is laminar.
range: 0...25 500 (rounded to hundreds)
0: the default limit of 1 000 will be used
This display will only be indicated if the SuperUser mode is activated and
Profile bounds
=
user
is selected.
INIT-resis-
tant
A: Bad soundspeed
thresh. 2007 m/s
A: Bad soundspeed
offset: +321
Quant. wrapping
off
>ON<
Quantity recall
off
>ON<
Do not total. if
no meas.>
0 s
Total digits
↕
Automatic
3xC clear totals
off
>ON<
Show
Σ
Q
off
>ON<
Keep display val
off
>ON<
Turbulence mode
off
>ON<
Calibrat. data
↕
for Channel
A:
A:Profile bounds
factory
>USER<
Laminar flow
ifR*<
0