![Flexco FL-L-EC Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/flexco/fl-l-ec/fl-l-ec_installation-operation-and-maintenance-manual_2304543043.webp)
43
5.4.1 Application on the Upper Flange continued
Section 5 – Operation And Handling
Step 7a: Remove belt lifters
As described in Step 3 and Step 4, remove the troughing belt pins, lower the troughing belt into a flat
position, and insert the troughing belt pins again. Slide the belt lifter safely away from the conveyor belt
construction and bring the extendable foot sections as far inwards as possible, so that the device can be
safely transported and stored. Reinsert the blade pins.
5.4.2 Application on the Return Belt
A lifting rod for the return belt is included in the Flex-Lifter standard range of equipment for sizes M
and L. This is optional for Flex-Lifter size XL.
Step 4b: Adjust the width of the lifting rod to match the belt width
Information!
The straight lifting rods in sizes M and L each have an extension rod, see Figure 29. The V-shaped
angular lifting rods (size XL) each have two extension rods at both ends, see Figure 30.
Fig. 29
Lifting rods, sizes M and L
Fig. 30
Lifting rods, size XL
Remove the safety bolts, and adjust the width by moving the extendable extension rod(s). The extension
rods have holes for the insertion of the securing bolts.
Do not pull the extendable extension rod(s) too far out. The safety bolt must always be inserted through
a bore hole in the extension rod, or else it will be unstable. Reinsert safety bolt, and tighten it with a nut.
Содержание FL-L-EC
Страница 55: ......