![Flexco FL-L-EC Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/flexco/fl-l-ec/fl-l-ec_installation-operation-and-maintenance-manual_2304543018.webp)
18
Flex-Lifter Belt Lifters
Section 3 – Product Description
3.2.4 Reaction of the Flex-Lifter in the Event of Overloading
A shear pin is installed in the lifting mechanism of the Flex-Lifter. In the case of a critical overload, the
thread of the lifting mechanism is damaged, or the shear pin shears off. Lifting is no longer possible.
The device must be safely relieved. It is not permitted to continue using the damaged device. Contact
the supplier (see the inside front page for the address), to have the device repaired correctly and
professionally.
Information!
Limit the torque of a power tool (power wrench) belonging to a client to a maximum of 52Nm. This is
sufficient for raising the permitted loads. Do not push against the stop at full torque when lowering. This
can damage the thread. Clean the device regularly, and grease the moving parts on a regular basis, so
that the lifting mechanism will continue to run smoothly.
3.2.5 Permissible Towable Load of the Lifting Rod
Lifting rods with chains are used as devices for lifting return belts. The chains are secured to the flat ends
of the troughing belts with safety bolts.
The maximum towing capacity per fixing point is:
Size M
Size L
Size XL
Towing capacity, max.
225kg
340kg
340kg
Chart 3 Maximum towing capacity per fixing point
Information!
The statements on the original signs on the device are binding.