FIREPLACE OPERATION
ON/OFF OPERATION
The Flare Fireplaces Honeywell ignition system is provided with a 110V plug that can be connected to a controlled outlet for
ON/OFF operation of the fireplace. The electrical plug can also be removed in order to connect directly for hardwire operation.
The ON Off operation of the Flare Fireplaces with a Honeywell valve is controlled by switching ON or Off power supply to the
fireplace plug or hardwire.
The Fireplace will attempt to start whenever electric power is supplied to it. The Fireplace power supply needs to be wired by
QUALIFIED ELECTRICIAN.
The electrician can provide the operator a switch to control the outlet the fireplace is connected to.
The use of the plug should only be done when access to the outlet is available even after installation is completed.
This appliance must be grounded. In the event of a malfunction or breakdown, grounding provides a path of least resistance for
electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
Manual Gas Shutoff
–
All Flare Fireplaces must be installed with an accessible manual Gas shutoff (Not included) . Please use you
local building code for details on the manual gas shutoff requirements.
WALL SWITCH
–
OPTIONAL
The Fireplace ON/OFF operation can be done with a standard wallswitch provided. The wallswitch connection to the
fireplace must be wired by a qualified electrician. The switch will be set to control the supply of 110V to the fireplace
outlet or hardwire input.
Содержание Corner Right & Left 120
Страница 65: ...65 P a g e COMBUSTIBLE FINISHING MATERIAL CLEARANCES ...
Страница 71: ...71 P a g e EXAMPLES OF HEAT RELEASES ...
Страница 77: ...77 P a g e ELECTRIC AND CONTROL ELECTRIC DIAGRAM SCREEN MV MV PV PV ...
Страница 78: ...78 P a g e ELECTRIC DIAGRAM DOUBLE GLASS OR PV Double Glass Fan Plug No use MV MV PV PV ...
Страница 80: ...80 P a g e ELECTRIC DIAGRAM PV SYSTEM Ports 49 47 are connected to J6 on fireplace main board ...