70 |
P a g e
AIR INTAKE
Flare Fireplace offers units with Double Glass or an optional Blower Kit require air intake below the glass. This allows air
circulation which cools the external glass and increases the efficiency of the fireplace. See diagram on page 63.
Lower Air Intake
-
Optional
for normal safety screen installation.
Required
for installation with double glass or safety screen with optional
blower kit.
The size of the air intake will depend on the number of units used to assemble your large unit.
For fireplaces sized
80” & 100”
–
vent area must be at least
100 open square inches.
For fireplaces sized
60” & 70”
- vent area must be at least
70 open square inches
.
For fireplaces sized
50”
and below - vent area must be at least
50 open square inches.
For See Through and Room Definer fireplaces, the air intake requirements are
double
.
NOTE: Openings above for Heat Release and Air Intake are measured for open air space.
Lower vent opening can also be used as an access door to the gas valve, if it meets both requirements in terms of size. Lower
vent opening can be installed at the sides of the enclosure (one on every side), back or front. It is recommended to place one
opening on either side of longer units, to allow for better distribution across all fans of air taken in from the bottom.
Size
Vent Size
Units Size
Flare 120
2 x 5x8
2 x
70 square inches
–
Total 140
in
2
Flare 140
2 x 5x8
2 x
70 square inches
–
Total 140
in
2
Flare 160
2 x 5x8
2 x
100 square inches
–
Total 200
in
2
Flare 180
3 x 5x8
3 x
70 square inches
–
Total 210
in
2
Flare 200
2 x 5x8
2 x
100 square inches
–
Total 200
in
2
Flare 210
3 x 5x8
3 x
70 square inches
–
Total 210
in
2
Flare 240
3 x 5x8
3 x
100 square inches
–
Total 300
in
2
Flare 280
4 x 5x8
4 x
70 square inches
–
Total 280
in
2
Flare 300
3 x 5x8
3 x
100 square inches
–
Total 300
in
2
Flare 320
4 x 5x8
4 x
100 square inches
–
Total 400
in
2
Flare 400
4 x 5x8
4 x
100 square inches
–
Total 400
in
2
Содержание Corner Right & Left 120
Страница 65: ...65 P a g e COMBUSTIBLE FINISHING MATERIAL CLEARANCES ...
Страница 71: ...71 P a g e EXAMPLES OF HEAT RELEASES ...
Страница 77: ...77 P a g e ELECTRIC AND CONTROL ELECTRIC DIAGRAM SCREEN MV MV PV PV ...
Страница 78: ...78 P a g e ELECTRIC DIAGRAM DOUBLE GLASS OR PV Double Glass Fan Plug No use MV MV PV PV ...
Страница 80: ...80 P a g e ELECTRIC DIAGRAM PV SYSTEM Ports 49 47 are connected to J6 on fireplace main board ...