background image

 

 

Installation Location With Humidifier 

A humidifier should be  installed in the furnace  warm 

air  duct.  However,  it  may  be  installed  in  the  return  duct 
without  causing  problems  to  the  Air  Cleaner.  Care  must 
be  taken  to  ensure  that  the  humidifier  does  not  leak,  as 
this may cause arcing  and a mineral deposit to  build up 
on the collecting cells. 

An  atomizing  type  humidifier  should  be  installed 

downstream  from  the  Air  Cleaner.  If  the  atomizing  type 
humidifier is installed upstream, high humidity, salts  and 
minerals  may  decrease  the  efficiency  of  the  collecting 
cells and cause service problems. 

If  the  atomizing  type  humidifier  must  be  installed 

upstream, the following precautions should be taken: 
1.  Atomizing  type  humidifier  must  be  installed  as  far 

from the Air Cleaner as possible. 

2.  Collecting cells must be washed frequently to prevent 

a mineral deposit build-up. 

 
Installation Location With Air Conditioner 

Whenever  possible,  the  Air  Cleaner  should  be 

installed  upstream  of  the  cooling  coil.  This  location  will 
clean the air before it reaches the evaporator coil. 

MODEL 

DIMENSIONS — in  (cm)  

 

SASD10-2 

19.8 

(50.4) 

15.9 

(40.5) 

23.2 

(58.9) 

13.1 

(33.3) 

20.7 

(52.5) 

1.3 

(3.2) 

23.7 

(60.2) 

21.2 

(53.9) 

SASD11-2 

19.8 

(50.4) 

15.9 

(40.5) 

26.1 

(66.3) 

13.6 

(34.6) 

24.1 

(61.2) 

1.0 

(2.5) 

26.6 

(67.7) 

25.8 

(65.4) 

SASD12-2 

24.7 

(62.8) 

20.8 

(52.9) 

21.2 

(53.9) 

18.0 

(45.7) 

18.7 

(47.5) 

1.3 

(3.2) 

21.7 

(55.2) 

21.2 

(53.9) 

SASD18-2 

24.7 

(62.8) 

20.8 

(52.9) 

25.8 

(65.4) 

18.0 

(45.7) 

23.3 

(59.1) 

1.3 

(3.2) 

26.3 

(66.8) 

25.8 

(65.4) 

Fig. 3 — DIMENSIONS 

Fig. 4 — AIR CLEANER INSTALLATION LOCATION 

Allow 24 in (600 mm) clearance for cleaning air cleaner.  Allow 6 in. (150 mm) clearance for power box removal.

 

Содержание SASD10-2

Страница 1: ...i bacteria viruses and more down to 0 01 micron Dual Voltage Aluminum Collecting Cells are durable and easy to maintain Cell Guide ensures proper placement of collecting cells Activated Carbon Filters remove unpleasant odors Electronic Air Proving Switch for quick wiring optional Dual Indicator Lights show Air Cleaner is working at a glance Galvanized Steel Cabinet for solid vertical or horizontal...

Страница 2: ...e of electrostatic precipitation Millions of airborne pollutants are carried through the return air ducts of the heating cooling system and treated through four stages of filtration The prefilters 2 remove all large visible particles such as lint Smaller particles then pass through a two stage electrostatic collecting cell 2 First particles are given a powerful positive electrical charge by the io...

Страница 3: ...ir Cleaner will vary with CFM and whether the optional carbon filters have been installed in the unit Location The Air Cleaner must only be installed in the return air duct as close to the fan compartment as possible This location provides the most even airflow across the collecting cells and allows the Air Cleaner to keep the system motor and blower clean The installation can be vertical or horiz...

Страница 4: ...ype humidifier must be installed as far from the Air Cleaner as possible 2 Collecting cells must be washed frequently to prevent a mineral deposit build up Installation Location With Air Conditioner Whenever possible the Air Cleaner should be installed upstream of the cooling coil This location will clean the air before it reaches the evaporator coil 4 MODEL DIMENSIONS in cm A B C D E F G H SASD10...

Страница 5: ...ent direction than the left to right set up The handle should face the door Close access door Wiring Wiring should only be performed by qualified personnel only All wiring must comply with all applicable codes and standards The voltage of the power source must match the voltage indicated on the Air Cleaner The Air Cleaner must operate ONLY when the system fan is running Make sure the Air Cleaner i...

Страница 6: ...with DAX Detergent or a non chlorine non corrosive non abrasive liquid household detergent Allow detergent to run down both sides of plates and ionizing wires Let stand for 5 minutes or fill up laundry tub with water and DAX Detergent and dunk cells up and down until water is dirty 3 Rinse cells well with hot water maximum 120 F 49 C 4 To remove contaminate from the ionizing wires use an old tooth...

Страница 7: ...e from the power board Measuring High Voltage At Power Board A high voltage meter capable of measuring up to 10 000 VDC is required to test the voltage 1 The Air Cleaner should be ON with the cells installed the door closed and the system fan running The Air Cleaner should be on at least 5 minutes to allow voltage to stabilize The cells and ionizing wires must be clean 2 Remove the cover from powe...

Страница 8: ...board is turned on and the performance light will come on The light on the power switch will be lit even when the APS is open If the power board fails to come on with the fan on check that the sensor is properly set down to the bottom of the plastic bushing in the front of the power box To check the APS for proper operation remove the collecting cells turn the unit ON without the fan on The power ...

Страница 9: ... voltage meter 9 Replace the power box cover 10 Turn ON the Air Cleaner Setting Approximate Voltage Without High Voltage Meter A high voltage meter should be used to set the high voltage If one is not available this method can be used This will only set an approximate voltage After using this method the voltage should be reset with a high voltage meter as soon as possible 1 Remove power box cover ...

Страница 10: ...ove it from the cabinet 6 If you are removing the power box for any length of time tape a cover over the top opening to prevent air from entering into the system Replacing A Tungsten Ionizing Wire Replacement wires are cut to the correct length and have eyelets at each end for easy replacement 1 Turn OFF power to Air Cleaner 2 Remove cell from Air Cleaner 3 Remove all parts of broken wire from the...

Страница 11: ...9 D1 0509 D0 0509 D1 0509 11 Power Box Complete No Cover Depends on options with power box 12 Carbon Filters Set of 3 1156 3 1156 3 1856 3 1856 3 13 Prefilter R0 0855 R1 0855 R2 0855 R8 0855 14 Cell Guide Plastic R1 0603 R1 0603 R1 0603 R1 0603 15 Collecting Cell D0 0400 D1 0400 D2 0400 D8 0400 16 Cell Handle R1 0484 R1 0484 R1 0484 R1 0484 17 Door with Plastic Clip Handle D0 0632 D1 0632 D2 0632 ...

Страница 12: ...h needle nose pliers gently pull contacts down or replace contacts Cells arcing excessively power light and per formance indicator light ON or flashing Cells wet from washing Allow cells to dry completely Particles lodged in cell or broken ionizing wire Wash cell Shake particle out of cell Replace wire if necessary Ducts were not cleaned prior to installation of air cleaner Clean ducts Cell plates...

Страница 13: ...r basis for the Air Cleaner to function at its peak efficiency The frequency of cleaning will vary from one house to another On average the cells should be cleaned every 3 months Use the chart below to keep track of your cleaning schedule DATE CLEANED DATE CLEANED DATE CLEANED 13 ...

Страница 14: ...NOTES 14 ...

Страница 15: ...anties made in this warranty are exclusive and may not be altered enlarged or changed by any distributor dealer or other person whatsoever FIVE SEASONS COMFORT LIMITED WILL NOT BE RESPONSIBLE FOR 1 Normal maintenance as outlined in the Owner s Manual including cleaning of electronic collecting cells and or replacement of carbon filters 2 Damage or repairs required as a consequence of faulty instal...

Страница 16: ...d of the furnace or air handler ensure that there is 220 Volt output from these terminals when the unit is run manually and is running on low speed Some manufacturers do not supply full output voltage to the terminals in the low speed mode so the Air Cleaner will not function The green Performance Indicator Light will not turn on The Air Cleaner performs best when the system fan is on FAN ON or Co...

Отзывы: