Note:   

There  may  be  some  arcing  or  snapping  sounds 

from the collecting cells. This  is normal  when the unit is 
new.  In  about  2  weeks,  as  the  sharp  edges  of  the  cells 
become smoother, the arcing will disappear. 

 

OPERATION 

The Air Cleaner will run as long as there is adequate 

airflow  through  the  ducts.  The  Air  Cleaner  will  not  run  if 
the  system  fan  is  off.  For  proper  operation,  follow  these 
simple steps: 
1.  Run heating/cooling system fan continuously, and on 

low speed if available. 

2.  Remove  furniture  or  carpets  which  block  return  air 

grilles  throughout  your  house,  so  that  air  moves 
freely to the furnace/ air conditioner. 

3.  Check for proper operation of the system fan. 

 

WHITE DUST 

After  installation  of  the  Air  Cleaner,  you  may  notice 

some  white  dust  on  tabletops  and  shelves.  Most  large 
particles  such  as  lint,  are  too  heavy  to  remain  airborne 
and tend to settle quickly, never reaching the air cleaner. 

This  white  visible  dust  is  normally  referred  to  as 

clean dust.” As the Air Cleaner is removing the dark and 

staining particles from the air, the lint will also be cleaner. 

Lint  dust  is  most  noticeable  on  dark  furnishings;  in 

homes containing new carpeting; and where there is a lot 
of household traffic from occupants and pets. To reduce 
lint  dust,  use  continuous  fan  operation  and  keep  return 
vents unrestricted to create an efficient airflow. 

Note:  

The Air Cleaner does NOT produce more lint or 

dust.

 

MAINTENANCE 

It is important to follow a scheduled maintenance for 
maximum performance of the Air Cleaner. 

Cell And Prefilter Cleaning 

The collecting cells and prefilters must be cleaned on 

a regular basis for the Air Cleaner to function at its peak 
of    efficiency.  The  frequency  of  cleaning  will  vary  from 
one  house  to  another.  On  average,  the  cells  should  be 
cleaned every 3 months. 
1.  Remove access door, collecting cells and prefilters. 
2.  Place cells in a laundry tub. Rinse with hot water and 

spray  completely  with  DAX  Detergent  (or  a  non-
chlorine,  non-corrosive,  non-abrasive  liquid 
household  detergent.  Allow  detergent  to  run  down 
both sides of plates and ionizing wires. Let stand for 
5  minutes  or  fill  up  laundry  tub  with  water  and  DAX 
Detergent, and dunk cells up and down until water is 
dirty. 

3.  Rinse  cells  well  with  hot  water  (maximum  120°F/ 

49°

C). 

4.  To  remove  contaminate  from  the  ionizing  wires  use 

an  old  toothbrush.  Slide  the  brush  bristles  over  the 
wire and gently drag the brush up and down the wire 
once.  Be  very  careful  when  cleaning  the  wires  as 
they become very brittle with age. 

5.  If dirt remains on the cell plates, let the cells soak in a 

solution of DAX Detergent and water for 30 minutes. 

6.  Tilt cells on 45° angle on their short side, with arrows 

pointing  sideways.  Allow  to  dry  completely, 
approximately 12-24 hours. A hair dryer may be used 
to speed up drying time. 

7.  To  wash  prefilters,  spray  with  DAX  Detergent,  rinse 

and  let  dry.  Do  not  wash  in  the  same  water  as 
collecting cells. 

8. 

Do not place the cells in the air cleaner if they are 
wet.

 

9.  Place  cells  and  prefilters  back  into  cabinet.  Close 

door  and  turn  power  switch  ON.  If  the  performance 
light  does  not  come  on  or  arcing  occurs,  turn  Air 
Cleaner  OFF  and  allow  air  from  system  fan  to  dry 
cells completely. 

Activated Carbon Filter Replacement 

Carbon filters help remove odors from the air. Carbon 

filters should be replaced every 3 - 6 months. Filters are 
NOT washable. Replacements are available through your 
 

CAUTION  

Make  sure  to  turn  Air  Cleaner  and  system  fan 

OFF 

before  performing  any  maintenance  or  removing  any 
components.  

CAUTION  

Damage  to  cells  may  occur  if  improperly  handled  or 
washed. Do  not  wash cells in a dishwasher. Never  use 
any object to clean between the cell plates, as this may 
cause  damage  to  plates  or  ionizing  wires.  Never  place 
cell in oven to dry. The edges of the cell may be sharp - 
handle with care.  

 

Replacement Carbon Filters: 
SASD10-2, SASD11-2       Set of 3       Part #1156-3 
SASD12-2, SASD18-2       Set of 3       Part #1856-3 

Fig. 6 

 DAX Detergent and Carbon Filters are 

available from your installer or dealer. 

DAX 

 

32 oz Spray Bottle 

Part #FS9900 

Содержание SASD10-2

Страница 1: ...i bacteria viruses and more down to 0 01 micron Dual Voltage Aluminum Collecting Cells are durable and easy to maintain Cell Guide ensures proper placement of collecting cells Activated Carbon Filters remove unpleasant odors Electronic Air Proving Switch for quick wiring optional Dual Indicator Lights show Air Cleaner is working at a glance Galvanized Steel Cabinet for solid vertical or horizontal...

Страница 2: ...e of electrostatic precipitation Millions of airborne pollutants are carried through the return air ducts of the heating cooling system and treated through four stages of filtration The prefilters 2 remove all large visible particles such as lint Smaller particles then pass through a two stage electrostatic collecting cell 2 First particles are given a powerful positive electrical charge by the io...

Страница 3: ...ir Cleaner will vary with CFM and whether the optional carbon filters have been installed in the unit Location The Air Cleaner must only be installed in the return air duct as close to the fan compartment as possible This location provides the most even airflow across the collecting cells and allows the Air Cleaner to keep the system motor and blower clean The installation can be vertical or horiz...

Страница 4: ...ype humidifier must be installed as far from the Air Cleaner as possible 2 Collecting cells must be washed frequently to prevent a mineral deposit build up Installation Location With Air Conditioner Whenever possible the Air Cleaner should be installed upstream of the cooling coil This location will clean the air before it reaches the evaporator coil 4 MODEL DIMENSIONS in cm A B C D E F G H SASD10...

Страница 5: ...ent direction than the left to right set up The handle should face the door Close access door Wiring Wiring should only be performed by qualified personnel only All wiring must comply with all applicable codes and standards The voltage of the power source must match the voltage indicated on the Air Cleaner The Air Cleaner must operate ONLY when the system fan is running Make sure the Air Cleaner i...

Страница 6: ...with DAX Detergent or a non chlorine non corrosive non abrasive liquid household detergent Allow detergent to run down both sides of plates and ionizing wires Let stand for 5 minutes or fill up laundry tub with water and DAX Detergent and dunk cells up and down until water is dirty 3 Rinse cells well with hot water maximum 120 F 49 C 4 To remove contaminate from the ionizing wires use an old tooth...

Страница 7: ...e from the power board Measuring High Voltage At Power Board A high voltage meter capable of measuring up to 10 000 VDC is required to test the voltage 1 The Air Cleaner should be ON with the cells installed the door closed and the system fan running The Air Cleaner should be on at least 5 minutes to allow voltage to stabilize The cells and ionizing wires must be clean 2 Remove the cover from powe...

Страница 8: ...board is turned on and the performance light will come on The light on the power switch will be lit even when the APS is open If the power board fails to come on with the fan on check that the sensor is properly set down to the bottom of the plastic bushing in the front of the power box To check the APS for proper operation remove the collecting cells turn the unit ON without the fan on The power ...

Страница 9: ... voltage meter 9 Replace the power box cover 10 Turn ON the Air Cleaner Setting Approximate Voltage Without High Voltage Meter A high voltage meter should be used to set the high voltage If one is not available this method can be used This will only set an approximate voltage After using this method the voltage should be reset with a high voltage meter as soon as possible 1 Remove power box cover ...

Страница 10: ...ove it from the cabinet 6 If you are removing the power box for any length of time tape a cover over the top opening to prevent air from entering into the system Replacing A Tungsten Ionizing Wire Replacement wires are cut to the correct length and have eyelets at each end for easy replacement 1 Turn OFF power to Air Cleaner 2 Remove cell from Air Cleaner 3 Remove all parts of broken wire from the...

Страница 11: ...9 D1 0509 D0 0509 D1 0509 11 Power Box Complete No Cover Depends on options with power box 12 Carbon Filters Set of 3 1156 3 1156 3 1856 3 1856 3 13 Prefilter R0 0855 R1 0855 R2 0855 R8 0855 14 Cell Guide Plastic R1 0603 R1 0603 R1 0603 R1 0603 15 Collecting Cell D0 0400 D1 0400 D2 0400 D8 0400 16 Cell Handle R1 0484 R1 0484 R1 0484 R1 0484 17 Door with Plastic Clip Handle D0 0632 D1 0632 D2 0632 ...

Страница 12: ...h needle nose pliers gently pull contacts down or replace contacts Cells arcing excessively power light and per formance indicator light ON or flashing Cells wet from washing Allow cells to dry completely Particles lodged in cell or broken ionizing wire Wash cell Shake particle out of cell Replace wire if necessary Ducts were not cleaned prior to installation of air cleaner Clean ducts Cell plates...

Страница 13: ...r basis for the Air Cleaner to function at its peak efficiency The frequency of cleaning will vary from one house to another On average the cells should be cleaned every 3 months Use the chart below to keep track of your cleaning schedule DATE CLEANED DATE CLEANED DATE CLEANED 13 ...

Страница 14: ...NOTES 14 ...

Страница 15: ...anties made in this warranty are exclusive and may not be altered enlarged or changed by any distributor dealer or other person whatsoever FIVE SEASONS COMFORT LIMITED WILL NOT BE RESPONSIBLE FOR 1 Normal maintenance as outlined in the Owner s Manual including cleaning of electronic collecting cells and or replacement of carbon filters 2 Damage or repairs required as a consequence of faulty instal...

Страница 16: ...d of the furnace or air handler ensure that there is 220 Volt output from these terminals when the unit is run manually and is running on low speed Some manufacturers do not supply full output voltage to the terminals in the low speed mode so the Air Cleaner will not function The green Performance Indicator Light will not turn on The Air Cleaner performs best when the system fan is on FAN ON or Co...

Отзывы: