installer or dealer. To replace filters, perform the following 
functions: 
1.  Turn Air Cleaner power switch 

OFF

2.  Turn off system fan. 
3.  Open access door. 
4.  Remove collecting cells from Air Cleaner. 
5.  Remove the used carbon filters from Air Cleaner.  
6.  Put  new carbon filters  into Air  Cleaner. Space filters 

evenly  across  the  discharge  opening  of  Air  Cleaner. 
Never  put  more  than  3  carbon  filters  in  the  Air 
Cleaner, as this may cause a problem with airflow. 

SERVICE

 

The  Air  Cleaner  when  operating  normally,  with  the 

fan  running,  should  have  both  the  switch  light  and  the 
performance indicator light 

ON

. If the fan is running  and 

the  lights  are  not  on  see  the  Troubleshooting  Guide  for 
probable causes and remedies. 

 

Quick Check 

(Power Light ON, Performance

 

Light OFF)

 

1.  Make  sure  the 

system  fan  is  ON

Remove  both 

cells

2.  Close  the  door.  If  the  light  is  still  out,  check  the 

power board for an arc to ground at HV1 or HV2. If 
there  is  a  good  arc  and  no  performance  light  then 
replace  the  light.  If  the  light  comes  on  check  the 
cells for a fault. 

3.  If  there  is  no  arc,  test  the  output  voltage  of  the 

transformer.  If  there  is  transformer  output  replace 
the power board 

4.  If there is no transformer output, check for output of 

the APS. 

5.  If  there  is  output  from  the  APS,  replace  the 

transformer and retest the power board for an arc. 

6.  If there is no output from the APS, jumper terminals 

3 & 4 on the APS and retest the output. If there is 

APS output with the jumper, replace the APS. 

7.  If there is no output from the APS check the output 

voltage from the on/off switch. 

8.  If there is no voltage from the switch, test the input 

to the switch. If there is input, replace the switch. If 
there  is  no  input  to  the  switch,  check  the  interlock 
switch and the supply voltage. 

 
Testing For High Voltage At Power Board 

With the 

collecting cells out of the unit

, the door on 

the  unit  and  the  system  fan  on  high  speed,  turn  the  Air 
Cleaner 

ON

.  

With  a  long  shafted  screwdriver,  with  a  plastic 

handle,  short  between  the  grounded  side  of  the  power 
box and the HV1 terminal of the power board. 

If you draw a good spark, there is high voltage from 

the power board.  

 

Measuring High Voltage At Power Board

 

A  high  voltage  meter  capable  of  measuring  up  to 

10,000 VDC is required to test the voltage. 
1.  The Air Cleaner should be 

ON

 with the cells installed, 

the door closed and the system fan running. The Air 
Cleaner  should  be  on  at  least  5  minutes  to  allow 
voltage to stabilize. The cells and ionizing wires must 
be clean. 

2.  Remove the cover from power box. 
3.  Connect  the  ground  of  the  high  voltage  meter  to  an 

unpainted surface in the power box. 

4.  Check terminals HV1 and HV2 on the power board to 

determine  if  voltage  is  present.  See  Table  3  for 
values. 

5.  If  no  voltage  is  present,  remove  both  cells  from  the 

Air Cleaner and replace door. 
a.  Check the voltage at HV1 and HV2 again. 
b.  If  voltage  is  present,  the  problem  is  with  one  of 

the cells or the wiring to the copper contacts. 

c.  With  a  flashlight,  look  into  the  cabinet  to  check 

condition of the copper contacts. 

d.  If the contacts are not bent, replace one cell and 

retest voltage. If cell is OK, test the other cell. If 
the  problem  is  with  a  cell,  see  Troubleshooting 
Guide. 

e.  If  there  is  no  voltage  with  both  cells  removed, 

check  the  power  board,  APS  and  transformer  to 
make sure that they are functioning correctly. 

6.  If there is  voltage  present, but  the performance light 

does not come on, replace light. 

7.  High  voltage  can  be  adjusted  with  high  voltage 

potentiometer if required. See Table 3. 

 
Replacing A Performance Light 

Before  replacing  the  performance  light,  turn 

OFF

 

power to the Air Cleaner at the source.  
1.  Remove the power box cover. 
2.  Disconnect the performance light wiring connected to 

the LED terminals on the power board. Carefully cut 
the wire ties from the wire bundle. 

WARNING  

Electronic  Air  Cleaners  use  high  voltage  (low 
amperage).  Only  trained  personnel  should  perform 
service. 

USE  CAUTION!

 Electric shock can cause injury 

or death.  

CAUTION  

For  most  troubleshooting,  the  cells  should  be 
removed  from  the  Air  Cleaner.

  A  short  in  one  of  the 

cells  will  cause  the  power  board  to  shutdown  and  the 
performance light will stay off. Unless otherwise directed 
remove the cells from the unit when testing.  

WARNING  

When  performing  LIVE  tests  in  the  power  box 

NEVER

 

touch  any  parts  other  then  what  are  mentioned  in  the 
tests.  Components  carry  dangerous  voltages  and 
extreme care must be taken. 

Содержание SASD10-2

Страница 1: ...i bacteria viruses and more down to 0 01 micron Dual Voltage Aluminum Collecting Cells are durable and easy to maintain Cell Guide ensures proper placement of collecting cells Activated Carbon Filters remove unpleasant odors Electronic Air Proving Switch for quick wiring optional Dual Indicator Lights show Air Cleaner is working at a glance Galvanized Steel Cabinet for solid vertical or horizontal...

Страница 2: ...e of electrostatic precipitation Millions of airborne pollutants are carried through the return air ducts of the heating cooling system and treated through four stages of filtration The prefilters 2 remove all large visible particles such as lint Smaller particles then pass through a two stage electrostatic collecting cell 2 First particles are given a powerful positive electrical charge by the io...

Страница 3: ...ir Cleaner will vary with CFM and whether the optional carbon filters have been installed in the unit Location The Air Cleaner must only be installed in the return air duct as close to the fan compartment as possible This location provides the most even airflow across the collecting cells and allows the Air Cleaner to keep the system motor and blower clean The installation can be vertical or horiz...

Страница 4: ...ype humidifier must be installed as far from the Air Cleaner as possible 2 Collecting cells must be washed frequently to prevent a mineral deposit build up Installation Location With Air Conditioner Whenever possible the Air Cleaner should be installed upstream of the cooling coil This location will clean the air before it reaches the evaporator coil 4 MODEL DIMENSIONS in cm A B C D E F G H SASD10...

Страница 5: ...ent direction than the left to right set up The handle should face the door Close access door Wiring Wiring should only be performed by qualified personnel only All wiring must comply with all applicable codes and standards The voltage of the power source must match the voltage indicated on the Air Cleaner The Air Cleaner must operate ONLY when the system fan is running Make sure the Air Cleaner i...

Страница 6: ...with DAX Detergent or a non chlorine non corrosive non abrasive liquid household detergent Allow detergent to run down both sides of plates and ionizing wires Let stand for 5 minutes or fill up laundry tub with water and DAX Detergent and dunk cells up and down until water is dirty 3 Rinse cells well with hot water maximum 120 F 49 C 4 To remove contaminate from the ionizing wires use an old tooth...

Страница 7: ...e from the power board Measuring High Voltage At Power Board A high voltage meter capable of measuring up to 10 000 VDC is required to test the voltage 1 The Air Cleaner should be ON with the cells installed the door closed and the system fan running The Air Cleaner should be on at least 5 minutes to allow voltage to stabilize The cells and ionizing wires must be clean 2 Remove the cover from powe...

Страница 8: ...board is turned on and the performance light will come on The light on the power switch will be lit even when the APS is open If the power board fails to come on with the fan on check that the sensor is properly set down to the bottom of the plastic bushing in the front of the power box To check the APS for proper operation remove the collecting cells turn the unit ON without the fan on The power ...

Страница 9: ... voltage meter 9 Replace the power box cover 10 Turn ON the Air Cleaner Setting Approximate Voltage Without High Voltage Meter A high voltage meter should be used to set the high voltage If one is not available this method can be used This will only set an approximate voltage After using this method the voltage should be reset with a high voltage meter as soon as possible 1 Remove power box cover ...

Страница 10: ...ove it from the cabinet 6 If you are removing the power box for any length of time tape a cover over the top opening to prevent air from entering into the system Replacing A Tungsten Ionizing Wire Replacement wires are cut to the correct length and have eyelets at each end for easy replacement 1 Turn OFF power to Air Cleaner 2 Remove cell from Air Cleaner 3 Remove all parts of broken wire from the...

Страница 11: ...9 D1 0509 D0 0509 D1 0509 11 Power Box Complete No Cover Depends on options with power box 12 Carbon Filters Set of 3 1156 3 1156 3 1856 3 1856 3 13 Prefilter R0 0855 R1 0855 R2 0855 R8 0855 14 Cell Guide Plastic R1 0603 R1 0603 R1 0603 R1 0603 15 Collecting Cell D0 0400 D1 0400 D2 0400 D8 0400 16 Cell Handle R1 0484 R1 0484 R1 0484 R1 0484 17 Door with Plastic Clip Handle D0 0632 D1 0632 D2 0632 ...

Страница 12: ...h needle nose pliers gently pull contacts down or replace contacts Cells arcing excessively power light and per formance indicator light ON or flashing Cells wet from washing Allow cells to dry completely Particles lodged in cell or broken ionizing wire Wash cell Shake particle out of cell Replace wire if necessary Ducts were not cleaned prior to installation of air cleaner Clean ducts Cell plates...

Страница 13: ...r basis for the Air Cleaner to function at its peak efficiency The frequency of cleaning will vary from one house to another On average the cells should be cleaned every 3 months Use the chart below to keep track of your cleaning schedule DATE CLEANED DATE CLEANED DATE CLEANED 13 ...

Страница 14: ...NOTES 14 ...

Страница 15: ...anties made in this warranty are exclusive and may not be altered enlarged or changed by any distributor dealer or other person whatsoever FIVE SEASONS COMFORT LIMITED WILL NOT BE RESPONSIBLE FOR 1 Normal maintenance as outlined in the Owner s Manual including cleaning of electronic collecting cells and or replacement of carbon filters 2 Damage or repairs required as a consequence of faulty instal...

Страница 16: ...d of the furnace or air handler ensure that there is 220 Volt output from these terminals when the unit is run manually and is running on low speed Some manufacturers do not supply full output voltage to the terminals in the low speed mode so the Air Cleaner will not function The green Performance Indicator Light will not turn on The Air Cleaner performs best when the system fan is on FAN ON or Co...

Отзывы: