321037
76
14 FAULT
FINDING
14.1
Compressor Won't Start - Dead
Checks to be carried out:
1. Check the fuse and power outlet.
2 Check that there is the correct voltage from the power module to the compressor.
3. Continuity test the 3 pin plug, terminal block and the harness to the compressor.
4. Check the compressor windings.
14.2
Compressor Won't Start - Hums
Possible Causes:
1. The voltage may be low e.g. 10% low. Test the voltage under load.
2. System pressures may not be equalised; too short an off cycle.
14.3
Compressor starts, runs and then stops
Possible Causes:
1. Low voltage - high voltage.
2. Check the compressor voltage matches the supply voltage.
3. The system may be grossly overcharged. Liquid refrigerant entering the compressor low side
causes slugging of oil.
4. Check the current draw – if an overload is detected, the compressor will try to restart.
5. The high pressure side may be fully or partially blocked. Very high head pressure. This is
normally a blockage before the condenser.
6. The condenser may be too hot, e.g. air movement blocked or ambient temperature too high.
The refrigerator may be too close to a heating appliance.
7. Check the compressor pipe connections.
Содержание RF175W
Страница 1: ...321037 Service Manual Active Smart Refrigerator Freezer Models RF195A RF175W...
Страница 19: ...321037 19 5 4 5 Condenser Mullion Layout Diagram 5 4 5...
Страница 77: ...321037 77 15 WIRING DIAGRAM 15 1 RF175 Wiring Diagram...
Страница 78: ...321037 78 15 2 RF175 Control Module Wiring Diagram...
Страница 79: ...321037 79 15 3 RF175 Ice Water Wiring Diagram...
Страница 80: ...321037 80 15 4 RF175 Ice Water Control Module Wiring Diagram...
Страница 81: ...321037 81 15 5 RF195A Ice Water Wiring Diagram...
Страница 82: ...321037 82 15 6 RF195A Ice Water Control Module Wiring Diagram...