321037
37
Fault Code 15
Reason:
The PC fan is drawing less current than is expected. Either the wiring is
open circuit or the fan is faulty.
Primary Action:
Check the PC fan wiring and connections at both the fan and the power
module.
Secondary Action:
Check the fan. If faulty, replace.
Fault Code 16
Reason:
The PC fan is drawing more current than is expected. Either the wiring is
shorted or the fan is faulty.
Primary Action:
Check the PC fan wiring and connections at both the fan and the power
module.
Secondary Action:
Check the fan. If faulty, replace.
Fault Code 17
Reason:
The FC fan is drawing less current than is expected. Either the wiring is
open circuit or the fan is faulty.
Primary Action:
Check the FC fan wiring and connections at both the fan and the power
module.
Secondary Action:
Check the fan. If faulty, replace.
Fault Code 18
Reason:
The FC fan is drawing more current than is expected. Either the wiring is
shorted or the fan is faulty.
Primary Action:
Check the FC fan wiring and connections at both the fan and the power
module.
Secondary Action:
Check the fan. If faulty, replace.
Fault Code 19
Reserved.
Fault Code 20
Reason:
The flapper heater current is low.
Primary Action:
Check the Molex connections for the flapper heater.
Secondary Action:
Check the resistance of the heater. If open circuit, replace the heater.
Fault Code 21
Reason:
The flapper heater current is high.
Primary action:
Check for short circuit of the heater. If faulty, replace the heater.
Fault Code 22
Reason:
The resistance of the PC sensor 2 is outside the normal range
(> 45K Ohms). Temperature PC2 sensor cold.
Primary Action:
Check the connection at the module. Check the resistance of the sensor.
Secondary Action:
Replace the sensor.
Fault Code 23
Reason:
The resistance of the PC sensor 2 is outside the normal range
(< 660 Ohms). PC 2 sensor hot.
Primary Action:
Check the connection of the sensor at the module. Check the resistance of
the sensor.
Secondary Action:
Replace the sensor.
Fault Code 24
Reason:
The resistance of the ice tray sensor is outside the normal range
(> 45K Ohms) Sensor cold.
Primary Action:
Check the connections of the sensor at the module. Check the resistance
of the sensor.
Secondary Action:
Replace the sensor.
Содержание RF175W
Страница 1: ...321037 Service Manual Active Smart Refrigerator Freezer Models RF195A RF175W...
Страница 19: ...321037 19 5 4 5 Condenser Mullion Layout Diagram 5 4 5...
Страница 77: ...321037 77 15 WIRING DIAGRAM 15 1 RF175 Wiring Diagram...
Страница 78: ...321037 78 15 2 RF175 Control Module Wiring Diagram...
Страница 79: ...321037 79 15 3 RF175 Ice Water Wiring Diagram...
Страница 80: ...321037 80 15 4 RF175 Ice Water Control Module Wiring Diagram...
Страница 81: ...321037 81 15 5 RF195A Ice Water Wiring Diagram...
Страница 82: ...321037 82 15 6 RF195A Ice Water Control Module Wiring Diagram...