The Refrigeration Cycle
The compressor discharges high pressure, high temperature gas into the condenser circuit. A loop
from this condenser coil forms the mullion heater around the front edge of the freezer compartment
of the cabinets to then enter the filter drier, which is mounted vertically in the unit compartment.
Now that the high-pressure gas has been condensed, the liquid refrigerant flows through the
capillary tube, which is soldered to the suction line as a heat exchanger, entering the evaporator
mounted in the freezer compartment. The liquid refrigerant then boils off due to the low suction
pressure applied to it within the evaporator from the compressor, causing the evaporator to get
very cold. (Note: A warm body moves to a colder body). This heat-laden vapour is drawn back to
the compressor by way of the suction line to start the cycle all over again.
Diagram 5.3