Installation Instructions
Seite 96 Panda PMS 8.000 NE - 42 NE Manual.R04 - Capture D: Installation Instructions
8.7.08
D.7 Generator 12 V DC System Installation
The Panda generators from 8.000 NE upwards have their own dynamo to charge a 12 V starter
battery.
It is recommended to install an additional starter battery for the generator.
The generator is then independent from the remaining battery set. This enables you to start the
genset at any time with its own starter battery even if the other batteries are discharged. A further
advantage of a separate starter battery is that it isolates the generator's electric system from the
rest of the boat's DC system, i.e. minus pole (-) is not connected electrically to Earth/Ground.
The generator is then Earth/Ground free.
D.7.1 Connection of the 12 V Starter Battery
The positive (+) battery cable is connec-
ted directly to the solenoid switch of the
starter.
Fig. D.7.1-1: Positive Battery Cable
The negative (-) battery cable is connec-
ted to the engine foot.
Note! The battery negative pole may not
be connected with the boat ground or with
the protective grounding of the 120 V
installation!
Fig. D.7.1-2: Negative Battery Cable
Содержание Panda PMS-HD 12-4KU
Страница 58: ...Generator Failure Seite 58 Panda PMS 8 000 NE 42 NE Manual R04 Kapitel B Generator Failure 8 7 08 Blank...
Страница 76: ...Maintenance Instructions Seite 76 Panda PMS 8 000 NE 42 NE Manual R04 Kapitel C Maintenance Instructions 8 7 08...
Страница 104: ...Installation Instructions Seite 104 Panda PMS 8 000 NE 42 NE Manual R04 Capture D Installation Instructions 8 7 08 Blank...
Страница 116: ...Tables Page 116 Panda PMS 8 000 NE 42 NE Manual Chapter E Tables HP3 120V 60 Hz DVS 400V 50 Hz DVS 120V 240V 60 Hz...
Страница 120: ...Tables Page 120 Panda PMS 8 000 NE 42 NE Manual Chapter E Tables...
Страница 122: ...Generator Data F 2 Capsule measurements...
Страница 148: ...Measurements Page 148 Panel Generator Control P6 RE0703_Kunde_eng R02 Chapter B Measurements 8 7 08 Intentionally Blank...