Installation Instructions
Seite 102 Panda PMS 8.000 NE - 42 NE Manual.R04 - Capture D: Installation Instructions
8.7.08
D.8.4 VCS Voltage Control
All Panda generators from Panda 8000 upwards are fitted with the electronic voltage control
"VCS" as standard.
The VCS controls the generator voltage and motor speed. A actuator on the injection pump can
increase the engine speed by up to 8%.
If the generator is run without load, the voltage should be 231V with a frequency of approx 48.5 to
49Hz. The frequency (equates to the speed) can be increased by up to 8%. This ensures that the
engine speed is increased when there is an extra load. The maximum speed is achieved when
80% load is reached.
The speed gauge is governed by an adjusting screw, above and below. Adjustment of this screw
may not occur without the expressive approval of the manufacturer.
All signals pass through the circuit board in the AC-Control box. The signal impulse for the actua-
tor is passed to the electric motor by means of the 5 core wire.
The generator maintains its full capability if the VCS has a defect.
In this case the base current must be raised to at least 240 V by adjusting the minimum setting on
the speed gauge, in order to ensure that the generator output voltage at 70% nominal load does
not drop below 215 V.
Fig. D.8.4-1: VCS Control
1
6
5
4
2
3
7
1. Connection measuring voltage
2. Adjusting booster voltage (do not adjust!)
3. Adjustment VCS-voltage
4. Connection VCS inlet
5. Electrical fuse (1.6 A, slow to blow)
6. Potentiometer for booster time
7. Connection for PC
Содержание Panda PMS-HD 12-4KU
Страница 58: ...Generator Failure Seite 58 Panda PMS 8 000 NE 42 NE Manual R04 Kapitel B Generator Failure 8 7 08 Blank...
Страница 76: ...Maintenance Instructions Seite 76 Panda PMS 8 000 NE 42 NE Manual R04 Kapitel C Maintenance Instructions 8 7 08...
Страница 104: ...Installation Instructions Seite 104 Panda PMS 8 000 NE 42 NE Manual R04 Capture D Installation Instructions 8 7 08 Blank...
Страница 116: ...Tables Page 116 Panda PMS 8 000 NE 42 NE Manual Chapter E Tables HP3 120V 60 Hz DVS 400V 50 Hz DVS 120V 240V 60 Hz...
Страница 120: ...Tables Page 120 Panda PMS 8 000 NE 42 NE Manual Chapter E Tables...
Страница 122: ...Generator Data F 2 Capsule measurements...
Страница 148: ...Measurements Page 148 Panel Generator Control P6 RE0703_Kunde_eng R02 Chapter B Measurements 8 7 08 Intentionally Blank...