General operation
8.7.08
Panel Generator Control P6+ RE0703_Kunde_eng .R02 - Chapter A: General operation Page 145
Configuration and setting sheet KE06
Standard jumpering for use as Slave-Panel in connection with two Maste-Slave-Adapters RE0706 and a Gene-
rator Control Panel P6+ RE0703 as Master-Panel. Panel for 24V-operation. (over attitude of solder jumper J101
alternatively 12V-operation is possible)
The safety device is installed with the value 0,63AT.
The circuit parts for 24V-operation are not equipped.
Jumper
Status
Conf.
Description
J1
closed
during operation of the start button heat is along-operated
open
XM
Function deactivated
J3
1-2
Dynamo excitation resistor 68R is switched on with Fuel-Pump (1)
2-3
Dynamo excitation resistor 68R is switched on with Panel-ON (1)
open
XM
Dynamo excitation resistor is deactivated
J101
closed
M
12V - operation
open
M
24V - operation
J201
1-2
T-Engine-input, for contact, which opens in case of error (2)
2-3
XM
T-Engine-input, for contact, which closes in case of error (2)
J202
1-2
Water leak-input / Replace air filter, for contact, which opens in case of error (2)
2-3
XM
Water leak-input / Replace air filter, for contact, which closes in case of error (2)
J203
1-2
Oil-Press-input, for contact, which opens in case of error (2)
2-3
XM
Oil-Press-input, for contact, which closes in case of error (2)
J204
1-2
AC-Fault-input / Fuel level, for contact, which opens in case of error (2)
2-3
XM
AC-Fault-input / Fuel level, for contact, which closes in case of error (2)
J205
1-2
T-Winding-input, for contact, which opens in case of error (2)
2-3
XM
T-Winding-input, for contact, which closes in case of error (2)
J206
1-2
M
Input Water leak has red LED and switches off
2-3
M
Input Water leak has yellow LED and does not switch off
J207
1-2
M
Input AC-Fault has red LED and switches off
2-3
M
Input AC-Fault has yellow LED and does not switch off
J208
1-2
M
DC-Control-Signal (-) = OK alternator
2-3
M
DC-Control-Signal (+) = OK three-phase alternator
J209
1-2
M
DC-Control-Signal (-) = OK alternator
2-3
M
DC-Control-Signal (+) = OK three-phase alternator
J210
closed
Input AC-Fault has Pull-Up-current
≥
10mA
open
XM
Input AC-Fault has Pull-Up-current
≥
2,5mA
Fig. A.7-2: Settings of soldered jumper for this configuration (column Conf.)
Содержание Panda PMS-HD 12-4KU
Страница 58: ...Generator Failure Seite 58 Panda PMS 8 000 NE 42 NE Manual R04 Kapitel B Generator Failure 8 7 08 Blank...
Страница 76: ...Maintenance Instructions Seite 76 Panda PMS 8 000 NE 42 NE Manual R04 Kapitel C Maintenance Instructions 8 7 08...
Страница 104: ...Installation Instructions Seite 104 Panda PMS 8 000 NE 42 NE Manual R04 Capture D Installation Instructions 8 7 08 Blank...
Страница 116: ...Tables Page 116 Panda PMS 8 000 NE 42 NE Manual Chapter E Tables HP3 120V 60 Hz DVS 400V 50 Hz DVS 120V 240V 60 Hz...
Страница 120: ...Tables Page 120 Panda PMS 8 000 NE 42 NE Manual Chapter E Tables...
Страница 122: ...Generator Data F 2 Capsule measurements...
Страница 148: ...Measurements Page 148 Panel Generator Control P6 RE0703_Kunde_eng R02 Chapter B Measurements 8 7 08 Intentionally Blank...