Maintenance Instructions
Seite/Page 92 Panda 8000-42NE PVMV-N.R01 - Kapitel/Chapter 7: Maintenance Instructions
10.5.11
Fig. 7.9-3: LAir filter
Loose the wing bolt and lift the frame that holds the air filter.
Change the air filter (MANN C2039).
representative picture
7.10 Exchange of the V-belt
The relative high ambient temperature in the closed sound insulated capsule (about 85°C) can be a reas on for a
reduced lifespan of the v-belts. It is possible that the "softener" in the rubber compound lose their effect after a short
operating time because the air in the sound insulated capsule can be relative warm and dry.
The v-belt must be controlled in a very short time interval. It can be happen to change the v-belt after some weeks
because of unfavorably conditions. Therefore the control is needed in an interval of 150 operating hours. The v-belt
ia a wearing part. It should be enough spare v-belts on board. We suggest to stand by the according service-packet.
Fig. 7.10-1: Alternator fixing screw
Loosen the fixing screw above the alternator.
representative picture