Maintenance Instructions
10.5.11
Panda 8000-42NE PVMV-N.R01 - Kapitel/Chapter 7: Maintenance Instructions Seite/Page 91
7.8
Exchange of the fuel filter
Fig. 7.8.0-1: Fuel filter
The exchange of the filter depends on the contamination of the fuel, should
take place at least all 300 operation hours. Before the exchange of the filter
the inlet must be clamped.
Remove the hoses from the used filter and fasten them to the new filter. The
arrow on the filter housing indicates the direction of the fuel flow. A clogged
filter causes a decreased power output of the generator
representative picture
7.9
Exchange the air filter
Fig. 7.9-1: Air filter
Open the combustion air housing by loosen the clamp at the cover.
representative picture
Fig. 7.9-2: Airfilter
Open the combustion air housing by loosen the clamp at the cover.
representative picture