Generator Failure
10.5.11
Panda 8000-42NE PVMV-N.R01 - Kapitel/Chapter 8: Generator Failure Seite/Page 103
ATTENTION!
Never work at the electrical cabinet, when the generator is running! Do not
contact the capacitor. Before working on the system read the section “Safety
first!” on Page 10.
Fig. 8.6.1-1: Capacitor
1) Switch off generator
2) Disconnect starter battery
3) Open AC-Control box
The capacitors are discharged, by short circuit the two contacts. In addition use the cone end of an isolated
screwdriver.
8.6.2 Checking the Capacitors
ATTENTION!
Before working (installation) on the System read the section "Safety Instruc-
tions" in this Manual.
Do not check the capacitors whilst the generator motor is running! Charged capacitors can be lethal. Do not contact
the capacitors with bare fingers or non-insulated metallic objects! In order to test the capacitors, the terminal lead
wires have to be disconnected using pliers or a screwdriver with insulated handle(s). Once the wires have been
removed, the capacitors must discharged by bridging the capacitor terminals together with a slot screwdriver with an
isulated handle.
Fig. 8.6.2-1: Capacitor
Discharge the capacitor
1. Screw driver blade
2. Capacitor connections
3. Capacitor
1
2
3
Содержание 22-4 HD PVMV-N
Страница 8: ...Seite Page 8 Kapitel Chapter 2 10 5 11 12 Measurements 153 12 1 Hole pattern 153 ...
Страница 25: ...General Instructions and Regulations 10 5 11 Chapter 1 General Instructions and Regulations Page 25 ...
Страница 52: ...Seite Page 52 10 5 11 Leere Seite Intentionally blank The Panda Generator ...
Страница 94: ...Seite Page 94 Panda 8000 42NE PVMV N R01 10 5 11 Leere Seite Intentionally blank Maintenance Instructions ...
Страница 154: ...Seite Page 154 Panel Generator Control P6 RE0703_Kunde_eng R06 1 10 5 11 Leere Seite Intentionally blank Measurements ...