The Panda Generator
Seite/Page 58 - Kaptitel/Chapter 6: The Panda Generator
9.12.14
Fig. 6.3.5-11: Terminal Block
Terminal block for remote control cable with fuses and
power relays
F1 fuse 15 A for DC wiring
F2 fuse 25 A for starter relay
Ks power relay for starter
K2 power relay for glow plugs
K3 power relay for fuel pump
6.3.6 The Operation Surveillance System
Fig. 6.3.6-1: Thermo-switch at Cylinder Head
Thermo-switch at cylinder head
The thermo-switch at the cylinder head serves to monitor the
generator temperature. All thermo-switches for the
generators from Panda 6.000 upward are two-pole (earthed),
so called „openers“. This means the contacts are open in
normal cases and close only when the limits have been
exceeded.
Fig. 6.3.6-2: Thermo-switch at exhaust connection
Thermo-switch at exhaust connection
If the impeller pump stops and delivers no more seawater,
the exhaust connection becomes extremely hot.
K2
Ks
K3
F1 F2
Содержание 10000/9
Страница 10: ...Seite Page 10 Kapitel Chapter 2 9 12 14 Leere Seite Intentionally blank...
Страница 62: ...The Panda Generator Seite Page 62 Kaptitel Chapter 6 The Panda Generator 9 12 14...
Страница 220: ...Tables Seite Page 220 Kaptitel Chapter 11 Tables 9 12 14...
Страница 244: ...Seite Page 244 Kapitel Chapter 13 General operation 9 12 14 Leere Seite Intentionally blank General operation...
Страница 246: ...Seite Page 246 Kapitel Chapter 14 Measurements 9 12 14 Leere Seite Intentionally blank Measurements...