ROTOTERM MR-TR

18

www.first.si

STATUS

POSSIBLE FAULT

REMEDY

LED  for  valve  closing  ( )  is  ON  on 

controller, mixing valve is opened, heating 

water line is hot

-  Motor  MV  120/…  rotation  direction  is 

inverted regarding mixing valve.

Check motor rotation direction left and 

right.

Temperature in the room is always the 

same regardless of program

Slide switch 1 is in position  

1 (

) or 

 

0 ( )

Set slide switch 1 to     position AUTO

Too cold in the room.

- Slide switch 5 in position

 

- Terminal  pins  9  and  10  on    room  unit  is 

inverted

- Knobs for temperature setting are set to 

low

- set selector switch 5 to  

  position  .

-  check  connection  of  room  unit 

AS2000-E

- set knobs (5 and 6) to higher level

At timer status “

 is cold in the room, 

at status “ “ is warmer.

- Terminal  pins  9  and  10  on    room  unit  is 

inverted

-  check  connection  of  room  unit 

AS2000-E

If T2 or T3 key is pressed, Er1 is 

displayed.

- Sensor T2 or T3 interrupted

- Sensors out of function

- Check T2 and T3 sensors.

If T2 or T3 key is pressed, Er2 is 

displayed.

- Sensor T2 or T3 short 

  circuited.

- Check T2 and T3 sensors.

The controller operating normally. 

Sometimes it happens that the controller 

repeatedly reset (off and on again).

In the system appears strong 

electromagnetic interference. Controller 

activates the built-in

protection against electromagnetic 

pulses.

Contact central service

After the completion of maintenance work on the heating system check:

 - el. connection of sensors, room unit, controller, actuator, pump

 - Check operation of pumps, mixing valve actuator

 - setting parameters on the room unit and the controller

 - position of slide switches on the room unit and the controller

YOUR’S PROGRAM

Write down your's program

switch 

cycle

1

2

3

4

5

6

7

8

temp. level

higher

lower

higher

lower

higher

lower

higher

lower

day

time

switch 

cycle

9

10

11

12

13

14

15

16

temp. level

higher

lower

higher

lower

higher

lower

higher

lower

day

time

FIRŠT ROTOTEHNIKA

Radegunda 54, 3330 Mozirje, Slovenia

PE VELENJE

Koroška cesta 56a, 3320 VELENJE, Slovenija

tel. +386 3 898 35 00, fax. +386 3 898 35 35

e-mail:[email protected], www.first.si

Содержание 21128

Страница 1: ...display Code Description 21128 ROTOTERM MR TR plus Heating controller MR TR Room unit AS 2000 E sensors AF BSVF BF mounting kit 21131 ROTOTERM MR TR Heating controller MR TR sensors AF BSVF BF mounti...

Страница 2: ...t When used with radiator version the sensor is located into the boiler in order to prevent condensation or overheating of the boiler In case the boiler temperature falls bellow the condensing tempera...

Страница 3: ...5 The under floor sensor of the controller prevents the under floor to get too hot thus prevents the unpleasant feeling of warmth in your feet When used with radiator version the sensor is located in...

Страница 4: ...pins PIN CONNECTION 1 2 Put side air sensor AF 2000 3 4 Mixed flow sensor VF2000 grey colour 5 6 Room unit AS2000 5 9 6 9 7 8 Floor sensor BF2000 or boiler sensor KF2000 red colour 9 N Neutral condui...

Страница 5: ...ltage cables 2 If the distances between sensors and controller are larger over 15 meter it is recommended the installation of VDR resistance of 25V It is installed by soldering at the point where the...

Страница 6: ...se you don t have protection against floor overheating MOUNTING OF BOILER SENSOR KF 2000 for radiator heating only Mount the sensor into the cap next to the other boiler sensors In case of 4 way mixin...

Страница 7: ...ars Sensor cables shall not be placed parallel to live power supply cables as in case of electric shock there is danger of induced current which can damage the controller or room unit In case that pow...

Страница 8: ...fference Troom between actual room temperature and required room temperature When T2 BF KF key is pressed the display shows floor temperature or temperature in the boiler When T3 AF key is pressed the...

Страница 9: ...t can be modified by means of heating curve ascent or descent Range of parallel curve shift for heating curve 1 0 SELECTION OF HEATING CURVE Heating curves represent an interconnection between outside...

Страница 10: ...to This setting specifies the temperature at which the controller switches off the pump when mixing valve is already closed This function enables that all heating units are uniformly cooled down afte...

Страница 11: ...value of ratio Programming is executed in three procedures For easier understanding see the diagram on the following page First procedure set the ratio of heating curve and parallel shift Second proce...

Страница 12: ...Additionally it is equipped with room temperature display Room unit AS 2000 E has additional switch on the right side It makes possible to choose two heating regimes temperature control of mixed flow...

Страница 13: ...inutes 10 key for setting hours 11 key for setting the day of the week 12 key for input the program 13 key RESET deletes time and program 14 Slide switch for unit operation ON temperature control of m...

Страница 14: ...of operation There are two operating modes if the switch 14 in the ON position provides frost protection room temperature 8 10 C if the switch 14 in the OFF position heating is switched off closes mix...

Страница 15: ...o a lower temperature On the display appears symbol which indicates switching to higher temperature 2 First switching cycle for switching to higher temperature On display appears symbol for first sett...

Страница 16: ...xt switch cycle etc Temporary heating regime change Temporary change of regime is valid till next switch cycle When you re in automatic mode slide switch 2 in position AUTO press to change the regime...

Страница 17: ...to position AUTO program is not set See the example of program settings the program is incorrectly configured for each switch cycle to a higher temperature is followed switch cycle to a lower temperat...

Страница 18: ...T3 sensors If T2 or T3 key is pressed Er2 is displayed Sensor T2 or T3 short circuited Check T2 and T3 sensors The controller operating normally Sometimes it happens that the controller repeatedly re...

Отзывы: