ROTOTERM MR-TR

14

www.first.si

Heating regime selector switch

Room unit has additional switch (14) on the right side. It makes possible to choose two heating regimes:

1. ON - heating dependents on exterior and internal room temperature (normal operation). 

With built-in temperature sensor it assures constant room temperature. With connection with controller 

ROTOTERM MR-TR it corrects temperature of mixed flow.

Two temperature levels can be set - day time and night time level. The design of the timer enables 

simple operation with keys as well as control of actual hour, day and heating conditions in any time. 

Additionally it is equipped with room temperature display.

2. OFF -  temperature control of mixed flow dependents only on exterior temperature

Room unit works independently of room temperature. This is suitably, when we have additional heating sources in 

the room (fireplace, ...). 

The temperature of mixed flow is dependents of heating curve. Room unit in this regime allows parallel shift of heating curve. 

Two temperature shifts can be set - day time and night time level. The design of the timer enables simple operation with keys 

as well as control of actual hour, day and heating conditions in any time. Additionally it is equipped with room temperature display. 

Warning!

When is regime selector switch in position OFF, then slide switch for choosing way of operating (3) does not assure 

protection against freezing, but it has function of stopping operation of controller. It closes the mixing valve. 

Slide switch for choosing the way of operation

There are two operating modes:

  -  if the switch (14) in the ON position provides frost protection (room temperature 8° -10°C)

   -  if the switch (14) in the OFF position - heating is switched off (closes mixing valve. In this mode there is no  

 

  protection against frost!

  

  - Automatic working according set program

BATTERY REPLACEMENT

IT IS RECOMMENDED TO REPLACE THE BATTERY CELL AT THE BEGINNING OF HEATING PERIOD 

IN ORDER TO ATTAIN RELIABLE OPERATION OF ROOM UNIT!

Use screwdriver to separate AS 2000-E from wall console: press the screwdriver in the notch on bottom 

part, lift it with hand and remove it.

AS 2000-E uses alkaline battery cell 2x LR06 1.5V. 

In the unit are inserted two LR06 alkaline battery LR06 1,5 V. Pull out the spent cartridges and replace 

them immediately with new ones (you have a few seconds for replacement to maintain set program).

AS 2000-E operates regardless the network conditions (during eventual current break downs programme 

is not deleted) due to supply from batteries. Life time of batteries cell is about 2 years from the date of 

in stallation of new one and it becomes worn out when the display becomes pale.

Use exclusively alkaline battery cells type LR 06 in order to pre vent leakage and damages to electronic 

circuit.

Do not put used batteries in your regular household rubbish. Take them to your local battery-

disposal point.

Do not throw this device away with your regular household waste.

You  must  take  electronic  equipment  to  a  local  tip  to  be  disposed  of  in  line  with  current 

regulations.

Never try to recharge standard batteries as they may explode.

Do not take batteries apart or throw them into a fire.

Do not short circuit batteries.

Содержание 21128

Страница 1: ...display Code Description 21128 ROTOTERM MR TR plus Heating controller MR TR Room unit AS 2000 E sensors AF BSVF BF mounting kit 21131 ROTOTERM MR TR Heating controller MR TR sensors AF BSVF BF mounti...

Страница 2: ...t When used with radiator version the sensor is located into the boiler in order to prevent condensation or overheating of the boiler In case the boiler temperature falls bellow the condensing tempera...

Страница 3: ...5 The under floor sensor of the controller prevents the under floor to get too hot thus prevents the unpleasant feeling of warmth in your feet When used with radiator version the sensor is located in...

Страница 4: ...pins PIN CONNECTION 1 2 Put side air sensor AF 2000 3 4 Mixed flow sensor VF2000 grey colour 5 6 Room unit AS2000 5 9 6 9 7 8 Floor sensor BF2000 or boiler sensor KF2000 red colour 9 N Neutral condui...

Страница 5: ...ltage cables 2 If the distances between sensors and controller are larger over 15 meter it is recommended the installation of VDR resistance of 25V It is installed by soldering at the point where the...

Страница 6: ...se you don t have protection against floor overheating MOUNTING OF BOILER SENSOR KF 2000 for radiator heating only Mount the sensor into the cap next to the other boiler sensors In case of 4 way mixin...

Страница 7: ...ars Sensor cables shall not be placed parallel to live power supply cables as in case of electric shock there is danger of induced current which can damage the controller or room unit In case that pow...

Страница 8: ...fference Troom between actual room temperature and required room temperature When T2 BF KF key is pressed the display shows floor temperature or temperature in the boiler When T3 AF key is pressed the...

Страница 9: ...t can be modified by means of heating curve ascent or descent Range of parallel curve shift for heating curve 1 0 SELECTION OF HEATING CURVE Heating curves represent an interconnection between outside...

Страница 10: ...to This setting specifies the temperature at which the controller switches off the pump when mixing valve is already closed This function enables that all heating units are uniformly cooled down afte...

Страница 11: ...value of ratio Programming is executed in three procedures For easier understanding see the diagram on the following page First procedure set the ratio of heating curve and parallel shift Second proce...

Страница 12: ...Additionally it is equipped with room temperature display Room unit AS 2000 E has additional switch on the right side It makes possible to choose two heating regimes temperature control of mixed flow...

Страница 13: ...inutes 10 key for setting hours 11 key for setting the day of the week 12 key for input the program 13 key RESET deletes time and program 14 Slide switch for unit operation ON temperature control of m...

Страница 14: ...of operation There are two operating modes if the switch 14 in the ON position provides frost protection room temperature 8 10 C if the switch 14 in the OFF position heating is switched off closes mix...

Страница 15: ...o a lower temperature On the display appears symbol which indicates switching to higher temperature 2 First switching cycle for switching to higher temperature On display appears symbol for first sett...

Страница 16: ...xt switch cycle etc Temporary heating regime change Temporary change of regime is valid till next switch cycle When you re in automatic mode slide switch 2 in position AUTO press to change the regime...

Страница 17: ...to position AUTO program is not set See the example of program settings the program is incorrectly configured for each switch cycle to a higher temperature is followed switch cycle to a lower temperat...

Страница 18: ...T3 sensors If T2 or T3 key is pressed Er2 is displayed Sensor T2 or T3 short circuited Check T2 and T3 sensors The controller operating normally Sometimes it happens that the controller repeatedly re...

Отзывы: