31
Connectors
The CoaXPress
®
protocol uses 75
Ω
coaxial cables. The CoaXPress
®
2.0 interface requires two cables
with male HD-BNC connectors (also known as Micro BNC).
CoaXPress cables with HD-BNC connectors.
Cable lengths
The maximum CXP
®
cable length supported for the connection is dependent of the cable used. Please
refer to the table below.
Table 15 - Maximum cable length for various cable references
Belden cable
1694A
4694R
4855R
4505R
4731R
Maximum cable
distance (m)
40
45
24
36
65
Belden qualified
frequency (GHz)
6
12
12
12
12
CoaX outer
diameter (mm)
6.96
6.96
4.04
5.92
10.16
Connector Indicator lamps
Each connection has its own indication lamp.
Table 16 - Connector indicator lamp states
State
Lamp
Indication
No power
Off
System booting
Solid orange
Powered, but nothing connected
Flash_1 red
Connection detection in progress, PoCXP
active
AlternateFlash_12_5
green/ orange
Shown for a minimum of 1s even if the
connection detection is faster
Connection detection in progress, PoCXP
not in use
Flash_12_5
orange
Shown for a minimum of 1s even if the
connection detection is faster
Device / Host connected; data being
transferred
Solid green
Device / Host connected; waiting for event
(e.g. trigger, trigger controlled exposure)
Flash_1_orange
Error during data transfer
(e.g., CRC error, single bit error detected)
500 ms red pulse
Содержание C-BLUE One
Страница 1: ...C BLUE One User Manual C BLUE One User Manual_20211129...
Страница 20: ...20...
Страница 21: ...21...
Страница 22: ...22...
Страница 23: ...23...
Страница 45: ...45 Example 1 of ExposureStart ExposureEnd Example 2 of ExposureStart ExposureEnd...