1.0

Important Notes

1

2.0

Fire Front

2

3.0

Clearances to Combustibles

2

4.0

Ventilation and Room Size

2

5.0

Operating Instructions

2

6.0

Combustion Spillage Monitoring System

3

7.0

Cleaning

3

8.0

Ceramics

3

9.0

Servicing

3

10.0

List of Replacement Parts

3

IMPORTANT NOTES

The installation and Servicing of this fire MUST only be carried out by a competent person (such
as a CORGI registered fitter) in accordance with the Gas Safety (Installation and Use) Regulations
1998, the relevant British Standards, Codes of Practice, the Building Regulations and the manu-
facturer's instructions.

Failure to comply with the above recommendations could lead to prosecution and invalidate the
appliance warranty. 

Please ensure you are handed all of the manufacturers documents on completion of the instal-
lation.  This will include these instructions.

Always keep a note of the installer's name and address, the original purchase receipt and the
date of installation for future reference.

The fire should be serviced regularly to ensure continued safe operation.  See the servicing sec-
tion of the Installation Instructions for further reference.

Parts of this appliance become naturally hot during use.  It is recommended that a suitable fire-
guard conforming to BS 8423 is used, especially where young children, pets, the elderly or infirm
are concerned.

The manufacturer of this appliance considers all surfaces as working surfaces with the exception
of the control knob, control panel and ash pan cover.

This appliance is intended as a secondary source of heat only, and should not be used in a room
without some form of background heating present.

Combustible items, such as flooring and furniture and soft wall coverings (such as blown vinyl
or embossed paper), low temperature surrounds etc may discolour if fitted too close to the fire.
See relevant section for further details on clearances to combustibles.  No combustible materi-
als or flooring should protrude onto the hearth.

This appliance incorporates a safety monitoring device (Oxygen Depletion Sensor).

DO NOT burn any foreign material on this fire. The coals must be of the correct type and laid out
in accordance with the relevant section of the these instructions.  Failure to do so may create a
hazard or lead to sooting.  Under no circumstances shall the appliance be used if the glass front
door or panel has been removed, damaged or is open.

The integral catalytic converter should be checked by the installer upon servicing to ensure there
are no defects or obstructions that may prevent the satisfactory flow of combustion products.
The expected life of the catalytic converter is in excess of 11,000 hours (10 years of normal use).
After this time the catalytic converter should be replaced.

WARNING: Due to the nature of this product the area around the top of the fire (i.e. the trim)
gets very hot. Care should be taken when operating the appliance.

1

1.0

Содержание P30G FXL01

Страница 1: ...EL LE ES SS S I IN NS SE ET T M MO OD DE EL L P P3 30 0G G I IN NS ST TA AL LL LA AT TI IO ON N A AN ND D U US SE ER R I IN NS ST TR RU UC CT TI IO ON NS S All instructions must be handed to user for...

Страница 2: ...FXL01...

Страница 3: ...installed in a living room This volume may include adjacent spaces but these spaces must not be separated by a door In order to convert from cubic feet ft3 to cubic metres m3 divide the room volume i...

Страница 4: ...vre is also required To reduce the possibility of draughts entering the room via the air vent we recommend the use of Black Hole or Vortex type vents featuring internal baffles It should be noted that...

Страница 5: ...con structed clearances and insulation must be as for a timber constructed wall 2 Insertion into a purpose made opening in the inner leaf of a cavity wall or a disused conven tional fireplace opening...

Страница 6: ...h this appliance must be adequately sealed to the wall and floor to prevent excess draughts from around the back of the fire The temperature rating of any surround used must be 150 C minimum A combust...

Страница 7: ...Ensure that the gas supply is isolated before commencing installation of the appli ance The fireplace opening and environment must be in compliance with specifications laid down in the appropriate se...

Страница 8: ...l of a property and is achieved by using either a surround with extended rebate or a false chimney breast of minimum 90mm internal depth A false chimney breast should be installed taking into account...

Страница 9: ...possible centrally under a block joint Clear out the block work in the area and insert the lintel by saw or stitch drill and chisel Do not dry bed the lintel always bed on mortar and securely slate pi...

Страница 10: ...ment IGE UP 7 Special attention must be paid to the location of studwork frames of the inner leaf and the appli ance positioned accordingly Wires and pipes that run within the wall must also be taken...

Страница 11: ...loss from the room when the fire is off GAS SUPPLY When the opening is ready for installation of the fire the gas supply can be routed via knockout holes Examples are shown in the diagram in section 6...

Страница 12: ...ing a suitable spanner to pull the appliance back into position to allow an even pull around the fireplace opening Visually inspect and repeat if necessary to achieve a good fit Note Surplus cable MUS...

Страница 13: ...supplied with this appliance The firefront shown in these instructions may differ form the one supplied with the appliance Fit the convector hood to the firebox by engaging the two mounting hooks into...

Страница 14: ...nce must not be commissioned and the manufacturer should be contacted for guidance BRIEFING THE CUSTOMER All instructions must be handed to the user for safekeeping Show the customer how to light and...

Страница 15: ...n serviceable item If this needs replacement remove the two M5 securing screws and remove the complete valve Replacement must be done using original manufacturers parts Re assembly in the reverse of r...

Страница 16: ...atalytic converter remove the hood and front fret then the glass panel The cat alytic converter retaining clamp is secured with 4 nuts and slip proof washers located on the inside of the firebox at th...

Страница 17: ...then cuts off Check pilot has extinguished Ensure room sizing and ventilation are adequate See Section 3 1and 4 1 Loose or faulty thermocouple rectify Blocked pilot replace Dirt or lint in pilot aera...

Страница 18: ...oncerned The manufacturer of this appliance considers all surfaces as working surfaces with the exception of the control knob control panel and ash pan cover This appliance is intended as a secondary...

Страница 19: ...toring system ODS system The requirements of other appliances operating in the space or room must be taken into con sideration when assessing ventilation requirements this will have been carried out b...

Страница 20: ...embly The hood should be lifted and pulled outwards Next remove the door by removing the 2 screws and disengaging the 2 lugs at the bottom The glass can be cleaned using a proprietory hob cleaner Test...

Отзывы: