USER INSTRUCTIONS
Section
Content
Page No
1.0
Important Notes
1
2.0
Fire Front
2
3.0
Clearances to Combustibles
2
4.0
Ventilation and Room Size
2
5.0
Operating Instructions
2
6.0
Combustion Spillage Monitoring System
3
7.0
Cleaning
3
8.0
Ceramics
3
9.0
Servicing
3
10.0
List of Replacement Parts
3
IMPORTANT NOTES
The installation and Servicing of this fire MUST only be carried out by a competent person (such
as a CORGI registered fitter) in accordance with the Gas Safety (Installation and Use) Regulations
1998, the relevant British Standards, Codes of Practice, the Building Regulations and the manu-
facturer's instructions.
Failure to comply with the above recommendations could lead to prosecution and invalidate the
appliance warranty.
Please ensure you are handed all of the manufacturers documents on completion of the instal-
lation. This will include these instructions.
Always keep a note of the installer's name and address, the original purchase receipt and the
date of installation for future reference.
The fire should be serviced regularly to ensure continued safe operation. See the servicing sec-
tion of the Installation Instructions for further reference.
Parts of this appliance become naturally hot during use. It is recommended that a suitable fire-
guard conforming to BS 8423 is used, especially where young children, pets, the elderly or infirm
are concerned.
The manufacturer of this appliance considers all surfaces as working surfaces with the exception
of the control knob, control panel and ash pan cover.
This appliance is intended as a secondary source of heat only, and should not be used in a room
without some form of background heating present.
Combustible items, such as flooring and furniture and soft wall coverings (such as blown vinyl
or embossed paper), low temperature surrounds etc may discolour if fitted too close to the fire.
See relevant section for further details on clearances to combustibles. No combustible materi-
als or flooring should protrude onto the hearth.
This appliance incorporates a safety monitoring device (Oxygen Depletion Sensor).
DO NOT burn any foreign material on this fire. The coals must be of the correct type and laid out
in accordance with the relevant section of the these instructions. Failure to do so may create a
hazard or lead to sooting. Under no circumstances shall the appliance be used if the glass front
door or panel has been removed, damaged or is open.
The integral catalytic converter should be checked by the installer upon servicing to ensure there
are no defects or obstructions that may prevent the satisfactory flow of combustion products.
The expected life of the catalytic converter is in excess of 11,000 hours (10 years of normal use).
After this time the catalytic converter should be replaced.
WARNING: Due to the nature of this product the area around the top of the fire (i.e. the trim)
gets very hot. Care should be taken when operating the appliance.